Skip to Content

Blast freezer EK-SR-180BC7-A05 C

Blast freezer EK-SR-180BC7-A05 C
Illustrative photo

Producer: Karyer · Line: EK-SR (Blast Freezers)

Product code: EK-SR-180BC7-A05 C

Cooling capacity i
23.04 kW
Air flow
25,614 m³/h
Fin spacing
7.0 mm
Fans
1 × ⌀800 mm

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Model nomenclature

How to read the code of this model.

  • A
    Model code (series): EK-SR — EK-SR - blast freezer
  • B
    Number of fans: 1 — Number of fans (one digit).
  • C
    Fan diameter: 80 — Ø800 mm
  • D
    Dimensional data - coil size letter: B — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows: C — 4 tube rows
  • F
    Fin spacing: 7 — Fin spacing about 7 mm
  • G
    Generation code: A — Generation A
  • H
    Fan data: 05 — Ø800: 400V/3Ph/50Hz, 4-pole

Data

Evaporator
Air flow 25,614 m³/h
External surface 87.9 m²
Inner volume 26.9 dm³
Fin spacing 7.0 mm
Fin materialAluminium
Net weight 472 kg
Fans
Quantity 1
Diameter 800 mm
Speed 1,310 rpm
Power 3,900 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 69.0 dB(A)
Sound power 93.0 dB(A)
Energy class E
Connections
Inlet Ø22
Outlet Ø42
Defrost
EK-SR-180BC7-A05 C None

Performance

No glide: dew, mid and bubble point give the same rating.

TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.

R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)

High speed (Δ)
21.952 kW
Low speed (Y)
19.284 kW

Capacity matrix [kW]

R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.

High speed (Δ)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 8.49 8.35 8.27 8.23 8.18 8.11 8.04 8.05 8.51 9.20 8.98 8.90 8.78 8.62
5 10.27 10.22 10.19 11.33 11.27 11.18 11.07 11.07 11.71 12.62 12.28 12.15 11.97 11.70
6 12.86 12.99 13.11 14.69 14.69 14.61 14.47 14.46 15.29 16.49 16.01 15.83 15.59 15.21
7 15.33 15.71 15.98 18.06 18.20 18.20 18.11 18.11 19.17 20.67 20.06 19.83 19.50 18.99
8 17.47 18.08 18.65 21.30 21.68 21.91 21.91 21.95 23.24 25.11 24.40 24.13 23.72 23.08
9 21.55 22.52 23.40 24.19 24.72 25.06 25.25 25.46 27.03 29.33 28.71 28.46 28.10 27.40
10 23.53 24.83 26.00 27.03 27.75 28.21 28.49 28.76 30.55 33.17 32.49 32.21 31.79 31.10

Low speed (Y)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 7.69 7.55 7.48 7.45 7.41 7.37 7.32 7.36 7.80 8.43 8.25 8.18 8.08 7.95
5 9.23 9.16 9.13 10.14 10.10 10.03 9.94 9.98 10.57 11.42 11.13 11.03 10.88 10.65
6 11.60 11.64 11.69 13.06 13.03 12.96 12.85 12.87 13.63 14.71 14.31 14.16 13.95 13.64
7 13.87 14.09 14.29 16.08 16.14 16.11 16.00 15.99 16.92 18.27 17.74 17.55 17.27 16.84
8 16.02 16.40 16.80 19.05 19.25 19.31 19.25 19.28 20.42 22.05 21.41 21.17 20.81 20.25
9 19.83 20.55 21.22 21.83 22.23 22.48 22.59 22.67 24.02 25.97 25.26 24.97 24.55 23.88
10 21.73 22.71 23.61 24.42 24.96 25.30 25.49 25.71 27.30 29.63 28.99 28.73 28.34 27.63

Standard ratings (EN 328 / Eurovent)

Standard condition Air inlet [°C] TD [K] High speed (Δ) [kW]Low speed (Y) [kW]
SC1 10 10 32.48628.991
SC2 0 8 21.95219.284
SC3 -18 7 18.13716.120
SC4 -25 6 13.11211.692
SC5 -34 6 12.90511.626

Dimensions

Dimension drawing of EK-SR-180BC7-A05 C
Dimension drawing
Dimensions as drawn
A 1760 mm
B 1360 mm
C 2790 mm
F 1310 mm
G 1770 mm
E 1365 mm
H 1393 mm
I 1790 mm
D IN 1 x Ø22
D OUT 1 x Ø42
Overall [mm]
Length 1760 mm
Width 1393 mm
Height 2790 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.