EK-SR-480CC7-A05 C
99.14 kW
Defrost: None
Product code: EK-SR-391DC7-A03 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 102,656 m³/h |
|---|---|
| External surface | 395.5 m² |
| Inner volume | 120.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 1,096 kg |
| Quantity | 3 |
|---|---|
| Diameter | 910 mm |
| Speed | 1,210 rpm |
| Power | 15,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 70.0 dB(A) |
|---|---|
| Sound power | 94.7 dB(A) |
| Energy class | E |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EK-SR-391DC7-A03 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 37.19 | 36.46 | 36.05 | 35.88 | 35.62 | 35.35 | 35.08 | 35.15 | 37.19 | 40.20 | 39.25 | 38.91 | 38.43 | 37.73 |
| 5 | 45.00 | 44.56 | 44.27 | 49.14 | 48.87 | 48.47 | 48.01 | 48.03 | 50.83 | 54.84 | 53.37 | 52.83 | 52.07 | 50.92 |
| 6 | 56.46 | 56.64 | 56.90 | 63.55 | 63.44 | 63.01 | 62.47 | 62.40 | 66.01 | 71.19 | 69.16 | 68.42 | 67.37 | 65.77 |
| 7 | 67.54 | 68.65 | 69.66 | 78.17 | 78.53 | 78.41 | 77.96 | 77.91 | 82.42 | 88.88 | 86.29 | 85.32 | 83.92 | 81.76 |
| 8 | 77.42 | 79.50 | 81.53 | 92.72 | 93.99 | 94.32 | 94.13 | 94.21 | 99.72 | 107.69 | 104.62 | 103.44 | 101.71 | 98.95 |
| 9 | 95.83 | 99.27 | 102.48 | 105.43 | 107.38 | 108.59 | 109.25 | 110.05 | 116.82 | 126.71 | 123.74 | 122.38 | 120.38 | 117.15 |
| 10 | 105.02 | 109.74 | 114.09 | 117.98 | 120.61 | 122.31 | 123.29 | 124.30 | 131.98 | 143.22 | 140.19 | 138.97 | 137.14 | 134.13 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 32.13 | 31.45 | 31.12 | 31.03 | 30.89 | 30.74 | 30.59 | 30.82 | 32.65 | 35.35 | 34.62 | 34.35 | 33.98 | 33.42 |
| 5 | 38.47 | 37.95 | 37.71 | 41.85 | 41.67 | 41.41 | 41.10 | 41.28 | 43.75 | 47.32 | 46.20 | 45.81 | 45.25 | 44.36 |
| 6 | 48.37 | 48.12 | 48.10 | 53.52 | 53.40 | 53.11 | 52.71 | 52.79 | 55.90 | 60.38 | 58.78 | 58.21 | 57.39 | 56.17 |
| 7 | 58.01 | 58.30 | 58.72 | 65.77 | 65.85 | 65.63 | 65.16 | 65.19 | 68.99 | 74.49 | 72.40 | 71.62 | 70.51 | 68.79 |
| 8 | 67.32 | 68.35 | 69.38 | 77.97 | 78.46 | 78.47 | 78.15 | 78.19 | 82.76 | 89.39 | 86.82 | 85.85 | 84.44 | 82.21 |
| 9 | 84.50 | 86.30 | 88.39 | 90.28 | 91.28 | 91.64 | 91.53 | 91.67 | 97.06 | 104.91 | 101.98 | 100.83 | 99.14 | 96.42 |
| 10 | 92.70 | 95.70 | 98.56 | 101.24 | 103.02 | 104.13 | 104.72 | 105.42 | 111.68 | 120.82 | 117.60 | 116.29 | 114.35 | 111.20 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 140.193 | 117.595 |
| SC2 | 0 | 8 | 94.214 | 78.194 |
| SC3 | -18 | 7 | 78.386 | 65.841 |
| SC4 | -25 | 6 | 56.901 | 48.095 |
| SC5 | -34 | 6 | 56.577 | 48.376 |
| A | 4360 mm |
|---|---|
| B | 1360 mm |
| C | 3390 mm |
| F | 1310 mm |
| G | 2370 mm |
| E | 3965 mm |
| H | 1393 mm |
| I | 4390 mm |
| D IN | 2 x Ø35 |
| D OUT | 2 x Ø54 |
| Length | 4360 mm |
|---|---|
| Width | 1393 mm |
| Height | 3390 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.