- Catalogue
- CO₂ DX evaporators
- EB-DC (Economical)
- EB-DC-430BC7-A01 C
CO2 evaporator EB-DC-430BC7-A01 C
Defrost: None
Product code: EB-DC-430BC7-A01 C
- Fin spacing
- 7.0 mm
- Fans
- 4 × ⌀300 mm
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
Model nomenclature
How to read the code of this model.
-
A
Model code (series): EB-DC — EB-DC - economical CO₂ (R744) DX unit cooler, max. 60 barg
-
B
Number of fans: 4 — Number of fans (one digit).
-
C
Fan diameter: 30 — Ø300 mm
-
D
Dimensional data - coil size letter: B — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
-
E
Dimensional data - tube rows: C — 4 tube rows
-
F
Fin spacing: 7 — Fin spacing about 7 mm
-
G
Generation code: A — Generation A
-
H
Fan data: 01 — Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole
Data
| External surface | 24.8 m² |
|---|---|
| Inner volume | 6.3 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 63 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 248 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.4 dB(A) |
| Energy class | C |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø15,9 |
| EB-DC-430BC7-A01 C | None |
|---|
Performance
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R744, dew point -8 °C, air inlet 0 °C (TD 8 K)
- Single phase
- 7.177 kW
Capacity matrix [kW]
R744, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
Single phase
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.04 | 3.04 | 3.10 | 3.18 | 3.25 | 3.31 | 3.36 | 3.46 | 3.70 | 4.06 | 4.05 | 4.05 | 4.05 | 4.06 |
| 5 | 3.79 | 3.83 | 3.91 | 4.02 | 4.12 | 4.20 | 4.27 | 4.38 | 4.68 | 5.14 | 5.11 | 5.10 | 5.09 | 5.08 |
| 6 | 4.53 | 4.60 | 4.72 | 4.87 | 4.99 | 5.10 | 5.19 | 5.31 | 5.68 | 6.22 | 6.18 | 6.16 | 6.13 | 6.09 |
| 7 | 5.25 | 5.36 | 5.51 | 5.70 | 5.85 | 5.99 | 6.10 | 6.25 | 6.67 | 7.31 | 7.25 | 7.23 | 7.19 | 7.12 |
| 8 | 5.94 | 6.09 | 6.28 | 6.51 | 6.71 | 6.88 | 7.01 | 7.18 | 7.66 | 8.39 | 8.33 | 8.30 | 8.25 | 8.16 |
| 9 | 6.60 | 6.79 | 7.04 | 7.31 | 7.55 | 7.75 | 7.92 | 8.11 | 8.66 | 9.47 | 9.40 | 9.37 | 9.31 | 9.20 |
| 10 | 7.24 | 7.48 | 7.78 | 8.10 | 8.38 | 8.61 | 8.81 | 9.03 | 9.64 | 10.55 | 10.48 | 10.44 | 10.37 | 10.24 |
Standard ratings (EN 328 / Eurovent)
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 10.482 |
| SC2 | 0 | 8 | 7.177 |
| SC3 | -18 | 7 | 5.761 |
| SC4 | -25 | 6 | 4.721 |
| SC5 | -34 | 6 | 4.550 |
Dimensions
| A | 2457 mm |
|---|---|
| B | 520 mm |
| C | 426 mm |
| F | 345 mm |
| E1 | 518 mm |
| E2 | 500 mm |
| E | 2035 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø15,9 |
| Length | 2457 mm |
|---|---|
| Width | 520 mm |
| Height | 415 mm |
Downloads
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.