- Catalogue
- Condensers
Condensers
12 lines. Filter by parameters or enter the capacity you need at your conditions.
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series KT = KT = commercial air-cooled condenser.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 17 = Ø170 mm20 = Ø200 mm23 = Ø230 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm50 = Ø500 mm63 = Ø630 mm
-
G
Coil tube rows (2nd dimensional letter) A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsD = 5 tube rowsE = 6 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm2 = 2.5 mm3 = 2.6-2.9 mm4 = 3.0-3.2 mm5 = 3.3-3.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation B
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = fan motor code; supply/poles vary with diameter02 = fan motor code; supply/poles vary with diameter03 = fan motor code; supply/poles vary with diameter04 = fan motor code; supply/poles vary with diameter05 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)07 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)08 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)09 = single-phase 230 V 50 Hz, 4-pole AC fan (in this series)10 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)19 = three-phase 400 V 50 Hz, 4-pole AC fan (in this series)
| Model | Heat rejection [kW] | Air flow [m³/h] | Fans | Compare |
|---|---|---|---|---|
| KT-120AB4-B04 C | 0.93 kW | 335 | 1 × ⌀200 | Compare |
| KT-t-123BB4-B01 C | 0.93 kW | 422 | 1 × ⌀230 | Compare |
| KT-t-120BA1-B04 C | 0.96 kW | 354 | 1 × ⌀200 | Compare |
| KT-120CB4-B04 C | 0.98 kW | 338 | 1 × ⌀200 | Compare |
| KT-t-120BD3-B03 C | 0.99 kW | 257 | 1 × ⌀200 | Compare |
| KT-120BB4-B04 C | 1.02 kW | 355 | 1 × ⌀200 | Compare |
| KT-120AB1-B04 C | 1.10 kW | 315 | 1 × ⌀200 | Compare |
| KT-123AA1-B02 C | 1.10 kW | 516 | 1 × ⌀230 | Compare |
| KT-120AC4-B04 C | 1.13 kW | 305 | 1 × ⌀200 | Compare |
| KT-120CB1-B04 C | 1.16 kW | 317 | 1 × ⌀200 | Compare |
| KT-120CC4-B04 C | 1.16 kW | 308 | 1 × ⌀200 | Compare |
| KT-120BB1-B04 C | 1.20 kW | 335 | 1 × ⌀200 | Compare |
| KT-123AB4-B02 C | 1.22 kW | 476 | 1 × ⌀230 | Compare |
| KT-t-125AA4-B04 C | 1.23 kW | 606 | 1 × ⌀250 | Compare |
| KT-120BC4-B04 C | 1.24 kW | 326 | 1 × ⌀200 | Compare |
| KT-120AD4-B04 C | 1.24 kW | 282 | 1 × ⌀200 | Compare |
| KT-120CD1-B04 C | 1.25 kW | 264 | 1 × ⌀200 | Compare |
| KT-120AD1-B04 C | 1.25 kW | 262 | 1 × ⌀200 | Compare |
| KT-125AA5-B05 C | 1.26 kW | 809 | 1 × ⌀250 | Compare |
| KT-120AC1-B04 C | 1.27 kW | 285 | 1 × ⌀200 | Compare |
| KT-217AB4-B03 C | 1.27 kW | 391 | 2 × ⌀170 | Compare |
| KT-120CD2-B04 C | 1.28 kW | 274 | 1 × ⌀200 | Compare |
| KT-120CC1-B04 C | 1.32 kW | 287 | 1 × ⌀200 | Compare |
| KT-t-123BD3-B01 C | 1.33 kW | 363 | 1 × ⌀230 | Compare |
Downloads
Every model has a product datasheet (PDF) with its data, the standard ratings SC1–SC5 and the capacity table: open a model and choose Product datasheet.
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.