Skip to Content

EA-DI (Cold Store)

Application
Cubic, Industrial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
16.06–167.55 kW
Fans
⌀630, ⌀800, ⌀910 mm
Max. working pressure
25 bar
EA-DI (Cold Store)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EA-DI = EA-DI - cold-store evaporator, fans inclined 45° to the coil
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 63 = Ø630 mm80 = Ø800 mm91 = Ø910 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). C = 4 tube rowsE = 6 tube rowsG = 8 tube rowsI = 10 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm7 = Fin spacing about 7 mm10 = Fin spacing about 10 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. A = Generation A
  • H
    Fan data 01 = Ø800: 400V/3Ph/50Hz, 6-pole04 = Ø910: 400V/3Ph/50Hz, 6-pole08 = Ø630: 400V/3Ph/50Hz, 4-pole13 = Ø630: 400V/3Ph/50Hz, 4-pole
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EA-DI-463GG7-A08 C 120.61 kW 7.0 4 × ⌀630 60,951 None
Variants (1)
EA-DI-380GI7-A01 C 121.02 kW 7.0 3 × ⌀800 50,084 None
Variants (1)
EA-DI-380GG4-A01 C 122.82 kW 4.6 3 × ⌀800 49,935 None
Variants (1)
EA-DI-363GI4-A13 C 123.33 kW 4.6 3 × ⌀630 47,656 None
Variants (1)
EA-DI-391GI10-A04 C 123.68 kW 10.0 3 × ⌀910 67,734 None
Variants (1)
EA-DI-463GE4-A13 C 125.94 kW 4.6 4 × ⌀630 69,781 None
Variants (1)
EA-DI-391GE4-A04 C 126.14 kW 4.6 3 × ⌀910 70,187 None
Variants (1)
EA-DI-463GG7-A13 C 126.89 kW 7.0 4 × ⌀630 69,192 None
Variants (1)
EA-DI-391GG7-A04 C 127.79 kW 7.0 3 × ⌀910 68,875 None
Variants (1)
EA-DI-491GE7-A04 C 130.58 kW 7.0 4 × ⌀910 100,722 None
Variants (1)
EA-DI-380GI4-A01 C 132.41 kW 4.6 3 × ⌀800 45,884 None
Variants (1)
EA-DI-480GG10-A01 C 134.33 kW 10.0 4 × ⌀800 75,990 None
Variants (1)
EA-DI-463GG4-A08 C 141.53 kW 4.6 4 × ⌀630 57,952 None
Variants (1)
EA-DI-480GE4-A01 C 144.21 kW 4.6 4 × ⌀800 73,210 None
Variants (1)
EA-DI-480GG7-A01 C 146.37 kW 7.0 4 × ⌀800 71,824 None
Variants (1)
EA-DI-491GG10-A04 C 147.03 kW 10.0 4 × ⌀910 97,004 None
Variants (1)
EA-DI-463GG4-A13 C 151.74 kW 4.6 4 × ⌀630 66,567 None
Variants (1)
EA-DI-491GE4-A04 C 158.91 kW 4.6 4 × ⌀910 93,583 None
Variants (1)
EA-DI-491GG7-A04 C 160.68 kW 7.0 4 × ⌀910 91,865 None
Variants (1)
EA-DI-480GG4-A01 C 167.55 kW 4.6 4 × ⌀800 66,576 None
Variants (1)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.