EA-DV-180GC4-A01 C
29.00 kW
Defrost: None
Product code: EA-DV-163GG10-A08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 15,708 m³/h |
|---|---|
| External surface | 105.5 m² |
| Inner volume | 43.4 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 284 kg |
| Quantity | 1 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 1,900 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 69.0 dB(A) |
|---|---|
| Sound power | 92.0 dB(A) |
| Energy class | D |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø54 |
| EA-DV-163GG10-A08 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 11.42 | 11.20 | 11.08 | 11.03 | 10.96 | 10.86 | 10.76 | 10.85 | 11.51 | 12.44 | 12.14 | 12.02 | 11.87 | 11.63 |
| 5 | 15.07 | 14.92 | 14.86 | 14.85 | 14.78 | 14.66 | 14.50 | 14.56 | 15.43 | 16.66 | 16.20 | 16.04 | 15.82 | 15.48 |
| 6 | 18.77 | 18.75 | 18.80 | 18.87 | 18.84 | 18.73 | 18.54 | 18.57 | 19.65 | 21.21 | 20.57 | 20.34 | 20.00 | 19.49 |
| 7 | 22.31 | 22.52 | 22.75 | 22.99 | 23.05 | 22.96 | 22.79 | 22.80 | 24.12 | 26.03 | 25.21 | 24.90 | 24.45 | 23.74 |
| 8 | 25.69 | 26.19 | 26.67 | 27.11 | 27.31 | 27.27 | 27.13 | 27.15 | 28.72 | 31.01 | 30.05 | 29.67 | 29.11 | 28.21 |
| 9 | 28.87 | 29.61 | 30.39 | 31.08 | 31.47 | 31.60 | 31.54 | 31.60 | 33.44 | 36.12 | 35.05 | 34.61 | 33.96 | 32.90 |
| 10 | 31.65 | 32.81 | 33.89 | 34.89 | 35.52 | 35.90 | 35.96 | 36.10 | 38.22 | 41.31 | 40.14 | 39.65 | 38.92 | 37.70 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 9.87 | 9.67 | 9.57 | 9.54 | 9.49 | 9.43 | 9.35 | 9.48 | 10.07 | 10.91 | 10.68 | 10.60 | 10.47 | 10.29 |
| 5 | 12.97 | 12.79 | 12.72 | 12.71 | 12.65 | 12.56 | 12.43 | 12.53 | 13.28 | 14.37 | 14.00 | 13.87 | 13.69 | 13.42 |
| 6 | 16.09 | 15.99 | 15.98 | 16.03 | 15.99 | 15.89 | 15.74 | 15.79 | 16.73 | 18.07 | 17.54 | 17.35 | 17.07 | 16.65 |
| 7 | 19.22 | 19.23 | 19.33 | 19.44 | 19.45 | 19.37 | 19.20 | 19.23 | 20.35 | 21.97 | 21.29 | 21.03 | 20.65 | 20.05 |
| 8 | 22.20 | 22.40 | 22.64 | 22.91 | 23.00 | 22.94 | 22.78 | 22.79 | 24.11 | 26.03 | 25.21 | 24.88 | 24.40 | 23.62 |
| 9 | 25.05 | 25.49 | 25.93 | 26.35 | 26.55 | 26.56 | 26.42 | 26.43 | 27.94 | 30.16 | 29.23 | 28.85 | 28.27 | 27.32 |
| 10 | 27.76 | 28.47 | 29.07 | 29.69 | 30.01 | 30.13 | 30.05 | 30.12 | 31.87 | 34.40 | 33.37 | 32.92 | 32.26 | 31.15 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 40.142 | 33.369 |
| SC2 | 0 | 8 | 27.151 | 22.793 |
| SC3 | -18 | 7 | 23.034 | 19.456 |
| SC4 | -25 | 6 | 18.802 | 15.980 |
| SC5 | -34 | 6 | 18.787 | 16.081 |
| A | 1725 mm |
|---|---|
| B | 1100 mm |
| C | 1260 mm |
| F | 1060 mm |
| G | 1785 mm |
| E | 1335 mm |
| D IN | 1 x Ø28 |
| D OUT | 1 x Ø54 |
| Length | 1725 mm |
|---|---|
| Width | 1785 mm |
| Height | 1260 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.