EA-163EG4-C06 C
17.55 kW
Defrost: None
Product code: EA-440AC7-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,931 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 48.8 m² |
| Inner volume | 16.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 103 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 640 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 64.0 dB(A) |
|---|---|
| Sound power | 86.0 dB(A) |
| Energy class | C |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| EA-440AC7-C01 C | None |
|---|---|
| EA-440AC7-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.35 | 6.28 | 6.24 | 6.21 | 6.16 | 6.08 | 6.00 | 6.06 | 6.40 | 6.90 | 6.70 | 6.63 | 6.54 | 6.39 |
| 5 | 8.53 | 8.58 | 8.63 | 8.68 | 8.66 | 8.59 | 8.48 | 8.54 | 9.05 | 9.76 | 9.47 | 9.38 | 9.24 | 9.03 |
| 6 | 10.70 | 10.92 | 11.13 | 11.30 | 11.35 | 11.32 | 11.23 | 11.29 | 11.96 | 12.90 | 12.50 | 12.35 | 12.15 | 11.84 |
| 7 | 12.64 | 13.05 | 13.45 | 13.82 | 14.06 | 14.18 | 14.13 | 14.21 | 15.06 | 16.26 | 15.77 | 15.58 | 15.31 | 14.87 |
| 8 | 14.32 | 14.94 | 15.51 | 15.97 | 16.32 | 16.54 | 16.65 | 16.84 | 17.89 | 19.43 | 19.00 | 18.82 | 18.56 | 18.13 |
| 9 | 15.88 | 16.65 | 17.42 | 18.12 | 18.61 | 18.92 | 19.10 | 19.33 | 20.54 | 22.32 | 21.84 | 21.63 | 21.33 | 20.80 |
| 10 | 17.32 | 18.33 | 19.33 | 20.23 | 20.87 | 21.29 | 21.55 | 21.84 | 23.22 | 25.23 | 24.71 | 24.48 | 24.13 | 23.50 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 24.714 |
| SC2 | 0 | 8 | 16.841 |
| SC3 | -18 | 7 | 13.927 |
| SC4 | -25 | 6 | 11.127 |
| SC5 | -34 | 6 | 10.762 |
| A | 2567 mm |
|---|---|
| B | 586 mm |
| C | 605 mm |
| F | 395 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 2235 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2567 mm |
|---|---|
| Width | 586 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.