ED-DP (Processing Room)
- Application
- Ceiling mounted (flat), Industrial
- Air discharge
- Dual
- Refrigerants
- R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
- Capacity
- 2.75–58.15 kW
- Fans
- ⌀350, ⌀400, ⌀450, ⌀630 mm
- Max. working pressure
- 25 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Model code (series) ED-DP = ED-DP - double-flow processing-room unit cooler
-
B
Number of fans — Number of fans (one digit).
-
C
Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm63 = Ø630 mm
-
D
Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
-
E
Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). C = 4 tube rowsE = 6 tube rowsG = 8 tube rows
-
F
Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.00, 7=7.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm7 = Fin spacing about 7 mm
-
G
Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation B
-
H
Fan data 22 = Ø350: 230V/1Ph/50Hz, 6-pole; Ø400: 230V/1Ph/50Hz, 6-pole24 = Ø450: 230V/1Ph/50Hz, 6-pole27 = Ø630: 400V/3Ph/50Hz, 6-pole
| Model | Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % | Fin spacing [mm] | Fans | Air throw [m] | Air flow [m³/h] | Defrost | Variants |
|---|---|---|---|---|---|---|---|
| ED-DP-445AE7-B24 C | 30.63 kW | 7.0 | 4 × ⌀450 | 13 | 13,769 | None |
Variants (1) |
| ED-DP-263AE7-B27 C | 30.90 kW | 7.0 | 2 × ⌀630 | 16 | 17,604 | None |
Variants (1) |
| ED-DP-445AE4-B24 C | 35.04 kW | 4.2 | 4 × ⌀450 | 12 | 12,694 | None |
Variants (1) |
| ED-DP-263AE4-B27 C | 35.50 kW | 4.6 | 2 × ⌀630 | 16 | 16,729 | None |
Variants (1) |
| ED-DP-263AG7-B27 C | 36.19 kW | 7.0 | 2 × ⌀630 | 15 | 16,477 | None |
Variants (1) |
| ED-DP-263AG4-B27 C | 39.97 kW | 4.6 | 2 × ⌀630 | 15 | 15,439 | None |
Variants (1) |
| ED-DP-363AE7-B27 C | 44.54 kW | 7.0 | 3 × ⌀630 | 20 | 26,412 | None |
Variants (1) |
| ED-DP-363AE4-B27 C | 52.27 kW | 4.6 | 3 × ⌀630 | 20 | 25,093 | None |
Variants (1) |
| ED-DP-363AG7-B27 C | 52.53 kW | 7.0 | 3 × ⌀630 | 19 | 24,718 | None |
Variants (1) |
| ED-DP-363AG4-B27 C | 58.15 kW | 4.6 | 3 × ⌀630 | 18 | 23,157 | None |
Variants (1) |
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
Downloads
- ED-DP-445AE7-B24 C — product datasheet (PDF)
- ED-DP-263AE7-B27 C — product datasheet (PDF)
- ED-DP-445AE4-B24 C — product datasheet (PDF)
- ED-DP-263AE4-B27 C — product datasheet (PDF)
- ED-DP-263AG7-B27 C — product datasheet (PDF)
- ED-DP-263AG4-B27 C — product datasheet (PDF)
- ED-DP-363AE7-B27 C — product datasheet (PDF)
- ED-DP-363AE4-B27 C — product datasheet (PDF)
- ED-DP-363AG7-B27 C — product datasheet (PDF)
- ED-DP-363AG4-B27 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.