ED-445AC4-C23 C
35.07 kW
Defrost: None
Product code: ED-250AG4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 12,282 m³/h |
|---|---|
| Air throw | 13 m |
| External surface | 182.6 m² |
| Inner volume | 40.3 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 184 kg |
| Quantity | 2 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,300 rpm |
| Power | 1,360 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 59.0 dB(A) |
|---|---|
| Sound power | 81.7 dB(A) |
| Energy class | C |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| ED-250AG4-C21 C | None |
|---|---|
| ED-250AG4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 13.75 | 13.92 | 14.12 | 14.32 | 14.40 | 14.40 | 14.32 | 14.66 | 15.63 | 16.98 | 16.65 | 16.55 | 16.40 | 16.21 |
| 5 | 17.43 | 17.87 | 18.29 | 18.68 | 18.87 | 18.91 | 18.82 | 19.11 | 20.30 | 22.03 | 21.45 | 21.23 | 20.93 | 20.46 |
| 6 | 21.03 | 21.79 | 22.49 | 23.11 | 23.42 | 23.56 | 23.49 | 23.75 | 25.19 | 27.31 | 26.51 | 26.19 | 25.72 | 24.94 |
| 7 | 24.27 | 25.39 | 26.44 | 27.37 | 27.97 | 28.27 | 28.25 | 28.51 | 30.18 | 32.69 | 31.74 | 31.34 | 30.72 | 29.68 |
| 8 | 27.11 | 28.64 | 30.05 | 31.14 | 31.98 | 32.47 | 32.63 | 33.01 | 35.03 | 37.98 | 37.00 | 36.56 | 35.83 | 34.54 |
| 9 | 29.72 | 31.71 | 33.33 | 34.91 | 36.02 | 36.66 | 36.95 | 37.39 | 39.68 | 43.00 | 41.92 | 41.40 | 40.60 | 39.20 |
| 10 | 32.10 | 34.35 | 36.59 | 38.57 | 39.98 | 40.83 | 41.26 | 41.78 | 44.34 | 48.05 | 46.87 | 46.29 | 45.38 | 43.78 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 46.867 |
| SC2 | 0 | 8 | 33.013 |
| SC3 | -18 | 7 | 27.640 |
| SC4 | -25 | 6 | 22.494 |
| SC5 | -34 | 6 | 21.223 |
| A | 2368 mm |
|---|---|
| B | 1350 mm |
| C | 405 mm |
| F | 1135 mm |
| G | 506 mm |
| E1 | 2035 mm |
| E2 | 1018 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 2368 mm |
|---|---|
| Width | 1350 mm |
| Height | 506 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.