Skip to Content

ED-P A (Commercial Double Flow)

Application
Ceiling mounted (flat), Commercial
Air discharge
Dual
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.83–2.97 kW
Fans
⌀250 mm
Max. working pressure
25 bar
ED-P A (Commercial Double Flow)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) ED-P = ED-P - commercial double-flow ceiling evaporator, plastic cabinet
  • B
    Design type — Karyer design type A, B or C ("A type is in grey, B and C in white colour"). A = Design type A (grey casing)B = Design type B (white casing)C = Design type C (white casing)
  • C
    Number of fans — Number of fans (one digit).
  • D
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 25 = Ø250 mm30 = Ø300 mm
  • G
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: ~4, 5, 6 (3.9 to 6.0 mm). The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm5 = Fin spacing about 5 mm6 = Fin spacing about 6 mm
  • H
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • I
    Fan data 24 = Ø250: 230V/1Ph/50Hz, 4-pole25 = Ø300: 230V/1Ph/50Hz, 4-pole
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
ED-P-A-125AC4-B24 C 0.83 kW 3.9 1 × ⌀250 2 470 None
Variants (1)
ED-P-A-125BC4-B24 C 0.88 kW 3.9 1 × ⌀250 2 469 None
Variants (1)
ED-P-A-125CD4-B24 C 0.95 kW 3.9 1 × ⌀250 2 434 None
Variants (1)
ED-P-A-225AC4-B24 C 1.68 kW 3.9 2 × ⌀250 3 948 None
Variants (1)
ED-P-A-225BC4-B24 C 1.78 kW 3.9 2 × ⌀250 3 947 None
Variants (1)
ED-P-A-225CD4-B24 C 1.90 kW 3.9 2 × ⌀250 3 876 None
Variants (1)
ED-P-A-325AC4-B24 C 2.48 kW 3.9 3 × ⌀250 4 1,426 None
Variants (1)
ED-P-A-325BC4-B24 C 2.61 kW 3.9 3 × ⌀250 4 1,425 None
Variants (1)
ED-P-A-325CD4-B24 C 2.97 kW 3.9 3 × ⌀250 4 1,317 None
Variants (1)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.