Skip to Content

ED-P C (Commercial Double Flow)

Application
Ceiling mounted (flat), Commercial
Air discharge
Dual
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.66–1.50 kW
Fans
⌀250, ⌀300 mm
Max. working pressure
25 bar
ED-P C (Commercial Double Flow)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) ED-P = ED-P - commercial double-flow ceiling evaporator, plastic cabinet
  • B
    Design type — Karyer design type A, B or C ("A type is in grey, B and C in white colour"). A = Design type A (grey casing)B = Design type B (white casing)C = Design type C (white casing)
  • C
    Number of fans — Number of fans (one digit).
  • D
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 25 = Ø250 mm30 = Ø300 mm
  • G
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: ~4, 5, 6 (3.9 to 6.0 mm). The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm5 = Fin spacing about 5 mm6 = Fin spacing about 6 mm
  • H
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • I
    Fan data 24 = Ø250: 230V/1Ph/50Hz, 4-pole25 = Ø300: 230V/1Ph/50Hz, 4-pole
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
ED-P-C-125AB5-B24 C 0.66 kW 4.8 1 × ⌀250 3 486 None
Variants (1)
ED-P-C-130BC5-B25 C 1.11 kW 4.8 1 × ⌀300 4 880 None
Variants (1)
ED-P-C-130AC5-B25 C 1.20 kW 4.8 1 × ⌀300 4 878 None
Variants (1)
ED-P-C-225AD5-B24 C 1.29 kW 4.8 2 × ⌀250 3 739 None
Variants (1)
ED-P-C-130AD5-B25 C 1.39 kW 4.8 1 × ⌀300 4 806 None
Variants (1)
ED-P-C-225AE5-B24 C 1.48 kW 4.8 2 × ⌀250 3 686 None
Variants (1)
ED-P-C-225BE5-B24 C 1.50 kW 4.8 2 × ⌀250 3 686 None
Variants (1)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.