EG-230BB4-C25 C
3.45 kW
Defrost: None
Product code: EG-230AC7-C25 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,282 m³/h |
|---|---|
| Air throw | 10 m |
| External surface | 9.9 m² |
| Inner volume | 2.7 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 34 kg |
| Quantity | 2 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 240 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 43.0 dB(A) |
|---|---|
| Sound power | 65.0 dB(A) |
| Energy class | D |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø19 |
| EG-230AC7-C25 C | None |
|---|---|
| EG-230AC7-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 1.31 | 1.30 | 1.30 | 1.30 | 1.30 | 1.29 | 1.28 | 1.31 | 1.39 | 1.50 | 1.47 | 1.46 | 1.44 | 1.41 |
| 5 | 1.73 | 1.74 | 1.76 | 1.78 | 1.78 | 1.77 | 1.76 | 1.78 | 1.89 | 2.05 | 2.00 | 1.98 | 1.95 | 1.92 |
| 6 | 2.14 | 2.18 | 2.23 | 2.27 | 2.29 | 2.29 | 2.27 | 2.30 | 2.44 | 2.64 | 2.56 | 2.53 | 2.49 | 2.42 |
| 7 | 2.52 | 2.60 | 2.67 | 2.75 | 2.79 | 2.82 | 2.81 | 2.84 | 3.01 | 3.26 | 3.17 | 3.13 | 3.07 | 2.98 |
| 8 | 2.86 | 2.97 | 3.08 | 3.18 | 3.24 | 3.28 | 3.30 | 3.34 | 3.55 | 3.86 | 3.77 | 3.73 | 3.67 | 3.56 |
| 9 | 3.21 | 3.35 | 3.49 | 3.61 | 3.69 | 3.75 | 3.77 | 3.82 | 4.06 | 4.41 | 4.31 | 4.26 | 4.19 | 4.07 |
| 10 | 3.51 | 3.70 | 3.87 | 4.03 | 4.14 | 4.21 | 4.25 | 4.31 | 4.58 | 4.97 | 4.86 | 4.80 | 4.72 | 4.58 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 4.855 |
| SC2 | 0 | 8 | 3.343 |
| SC3 | -18 | 7 | 2.768 |
| SC4 | -25 | 6 | 2.227 |
| SC5 | -34 | 6 | 2.154 |
| A | 1946 mm |
|---|---|
| B | 685 mm |
| C | 245 mm |
| F | 630 mm |
| E1 | 818 mm |
| E | 1635 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø19 |
| Length | 1946 mm |
|---|---|
| Width | 685 mm |
| Height | 245 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.