Skip to Content

EG (General)

Application
Ceiling mounted (slanted), Industrial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.93–13.31 kW
Fans
⌀250, ⌀300, ⌀350 mm
Max. working pressure
25 bar
EG (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EG = EG - angled ceiling-type unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). B = 3 tube rowsC = 4 tube rowsE = 6 tube rowsG = 8 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 7=7.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. C = Generation C
  • H
    Fan data 21 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole23 = Ø250: 230V/1Ph/50Hz, 4-pole25 = Ø300: 230V/1Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EG-235CG4-C21 C 8.92 kW 4.2 2 × ⌀350 12 3,183 None, Electric
Variants (2)
EG-430AE4-C25 C 8.93 kW 4.2 4 × ⌀300 12 3,611 None, Electric
Variants (2)
EG-430AE7-C21 C 9.09 kW 7.0 4 × ⌀300 15 4,630 None, Electric
Variants (2)
EG-430BE7-C21 C 9.13 kW 7.0 4 × ⌀300 15 4,631 None, Electric
Variants (2)
EG-430BE4-C25 C 9.76 kW 4.2 4 × ⌀300 12 3,611 None, Electric
Variants (2)
EG-430AE4-C21 C 9.90 kW 4.2 4 × ⌀300 14 4,239 None, Electric
Variants (2)
EG-335BC4-C21 C 9.98 kW 4.2 3 × ⌀350 20 6,780 None, Electric
Variants (2)
EG-335CE7-C21 C 10.66 kW 7.0 3 × ⌀350 19 6,061 None, Electric
Variants (2)
EG-430BE4-C21 C 10.87 kW 4.2 4 × ⌀300 14 4,239 None, Electric
Variants (2)
EG-335BE7-C21 C 11.43 kW 7.0 3 × ⌀350 19 6,433 None, Electric
Variants (2)
EG-335CE4-C21 C 11.70 kW 4.2 3 × ⌀350 17 5,473 None, Electric
Variants (2)
EG-335CG7-C21 C 12.07 kW 7.0 3 × ⌀350 17 5,382 None, Electric
Variants (2)
EG-335BE4-C21 C 13.11 kW 4.2 3 × ⌀350 18 5,884 None, Electric
Variants (2)
EG-335CG4-C21 C 13.31 kW 4.2 3 × ⌀350 15 4,774 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.