Skip to Content

EG-P (Commercial Angled Ceiling Type)

Application
Ceiling mounted (slanted), Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.54–1.67 kW
Fans
⌀230 mm
Max. working pressure
25 bar
EG-P (Commercial Angled Ceiling Type)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EG-P = EG-P - commercial angled ceiling evaporator, plastic cabinet
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 23 = Ø230 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). B = 3 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. C = Generation C
  • H
    Fan data 21 = Ø230: 230V/1Ph/50Hz, 4-pole
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EG-P-123AB4-C21 C 0.54 kW 3.8 1 × ⌀230 4 393 None
Variants (1)
EG-P-123BB4-C21 C 0.60 kW 3.8 1 × ⌀230 4 392 None
Variants (1)
EG-P-223AB4-C21 C 1.13 kW 3.8 2 × ⌀230 5 718 None
Variants (1)
EG-P-223BB4-C21 C 1.19 kW 3.8 2 × ⌀230 5 717 None
Variants (1)
EG-P-323AB4-C21 C 1.67 kW 3.8 3 × ⌀230 7 1,110 None
Variants (1)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.