Skip to Content

EL (Under Counter)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.24–0.47 kW
Fans
⌀120, ⌀170 mm
Max. working pressure
25 bar
EL (Under Counter)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EL = EL - under-counter cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter 12 = Ø120 mm15 = Ø150 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). E = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 5=5.50; fan 12=Ø120, 15=Ø150. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm5 = Fin spacing about 5 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. C = Generation C
  • H
    Fan data 21 = Ø120: 230V/1Ph/50Hz, 4-pole22 = Ø150: 230V/1Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EL-112AE4-C21 C 0.24 kW 4.2 1 × ⌀120 1 90 None, Electric
Variants (2)
EL-112BE4-C21 C 0.29 kW 4.2 1 × ⌀120 1 105 None, Electric
Variants (2)
EL-212AE4-C21 C 0.30 kW 4.2 2 × ⌀120 1 123 None, Electric
Variants (2)
EL-115AE5-C22 C 0.35 kW 5.5 1 × ⌀170 1 182 None, Electric
Variants (2)
EL-212BE4-C21 C 0.37 kW 4.2 2 × ⌀120 1 143 None, Electric
Variants (2)
EL-215AE5-C22 C 0.39 kW 5.5 2 × ⌀170 1 223 None, Electric
Variants (2)
EL-115BE5-C22 C 0.44 kW 5.5 1 × ⌀170 1 217 None, Electric
Variants (2)
EL-215BE5-C22 C 0.47 kW 5.5 2 × ⌀170 1 269 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.