EA-263GC10-C19 C
26.54 kW
Defrost: None
Product code: EA-350AC6-C09 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 20,812 m³/h |
|---|---|
| Air throw | 22 m |
| External surface | 74.5 m² |
| Inner volume | 23.2 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 139 kg |
| Quantity | 3 |
|---|---|
| Diameter | 500 mm |
| Speed | 1,330 rpm |
| Power | 2,130 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.2 dB(A) |
| Energy class | D |
| Inlet | Ø28 |
|---|---|
| Outlet | Ø54 |
| EA-350AC6-C09 C | None |
|---|---|
| EA-350AC6-C09 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 9.45 | 9.19 | 9.02 | 8.92 | 8.81 | 8.70 | 8.60 | 8.64 | 9.13 | 9.86 | 9.61 | 9.53 | 9.41 | 9.23 |
| 5 | 13.02 | 12.81 | 12.67 | 12.58 | 12.43 | 12.26 | 12.07 | 12.11 | 12.82 | 13.80 | 13.40 | 13.26 | 13.05 | 12.75 |
| 6 | 16.75 | 16.63 | 16.63 | 16.64 | 16.53 | 16.33 | 16.09 | 16.10 | 17.03 | 18.33 | 17.75 | 17.54 | 17.26 | 16.84 |
| 7 | 20.35 | 20.55 | 20.75 | 20.93 | 20.90 | 20.77 | 20.53 | 20.53 | 21.70 | 23.37 | 22.57 | 22.29 | 21.88 | 21.27 |
| 8 | 23.51 | 23.98 | 24.48 | 24.97 | 25.27 | 25.41 | 25.23 | 25.24 | 26.69 | 28.78 | 27.81 | 27.46 | 26.93 | 26.12 |
| 9 | 26.38 | 27.14 | 27.89 | 28.50 | 28.94 | 29.19 | 29.28 | 29.51 | 31.31 | 33.95 | 33.15 | 32.82 | 32.33 | 31.31 |
| 10 | 29.10 | 30.09 | 31.11 | 32.05 | 32.67 | 33.04 | 33.21 | 33.48 | 35.53 | 38.54 | 37.64 | 37.27 | 36.71 | 35.77 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 37.643 |
| SC2 | 0 | 8 | 25.237 |
| SC3 | -18 | 7 | 20.947 |
| SC4 | -25 | 6 | 16.629 |
| SC5 | -34 | 6 | 16.755 |
| A | 2937 mm |
|---|---|
| B | 590 mm |
| C | 715 mm |
| F | 510 mm |
| E1 | 868 mm |
| E2 | 850 mm |
| E | 2586 mm |
| D IN | 1 x Ø28 |
| D OUT | 1 x Ø54 |
| Length | 2937 mm |
|---|---|
| Width | 590 mm |
| Height | 685 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.