EA-263EG4-C01 C
34.55 kW
Defrost: None
Product code: EA-363ED7-C06 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 25,790 m³/h |
|---|---|
| Air throw | 24 m |
| External surface | 168.5 m² |
| Inner volume | 49.1 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 277 kg |
| Quantity | 3 |
|---|---|
| Diameter | 630 mm |
| Speed | 890 rpm |
| Power | 1,800 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 55.0 dB(A) |
|---|---|
| Sound power | 78.1 dB(A) |
| Energy class | D |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EA-363ED7-C06 C | None |
|---|---|
| EA-363ED7-C06 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 13.12 | 13.03 | 13.01 | 13.04 | 13.00 | 12.94 | 12.85 | 13.04 | 13.81 | 14.94 | 14.61 | 14.48 | 14.31 | 14.05 |
| 5 | 17.28 | 17.37 | 17.48 | 17.58 | 17.59 | 17.51 | 17.37 | 17.54 | 18.62 | 20.14 | 19.64 | 19.47 | 19.23 | 18.87 |
| 6 | 21.29 | 21.69 | 22.05 | 22.38 | 22.50 | 22.46 | 22.30 | 22.46 | 23.80 | 25.73 | 25.02 | 24.75 | 24.38 | 23.83 |
| 7 | 25.08 | 25.89 | 26.49 | 27.10 | 27.43 | 27.53 | 27.44 | 27.61 | 29.26 | 31.64 | 30.73 | 30.39 | 29.89 | 29.10 |
| 8 | 28.41 | 29.59 | 30.69 | 31.67 | 32.32 | 32.70 | 32.73 | 32.96 | 34.94 | 37.82 | 36.77 | 36.35 | 35.74 | 34.73 |
| 9 | 31.40 | 33.01 | 34.50 | 35.81 | 36.70 | 37.25 | 37.53 | 37.94 | 40.30 | 43.76 | 42.78 | 42.38 | 41.75 | 40.55 |
| 10 | 34.15 | 36.25 | 38.17 | 39.85 | 41.02 | 41.77 | 42.19 | 42.67 | 45.33 | 49.23 | 48.16 | 47.70 | 47.00 | 45.81 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 11.57 | 11.44 | 11.41 | 11.43 | 11.41 | 11.37 | 11.32 | 11.48 | 12.20 | 13.22 | 12.95 | 12.86 | 12.72 | 12.51 |
| 5 | 15.13 | 15.12 | 15.17 | 15.25 | 15.26 | 15.20 | 15.10 | 15.24 | 16.18 | 17.52 | 17.11 | 16.96 | 16.77 | 16.47 |
| 6 | 18.74 | 18.91 | 19.10 | 19.31 | 19.35 | 19.31 | 19.20 | 19.31 | 20.47 | 22.14 | 21.56 | 21.35 | 21.04 | 20.57 |
| 7 | 22.16 | 22.61 | 23.04 | 23.43 | 23.61 | 23.63 | 23.53 | 23.62 | 25.00 | 27.04 | 26.29 | 26.00 | 25.59 | 24.90 |
| 8 | 25.40 | 26.20 | 26.81 | 27.46 | 27.82 | 27.97 | 27.93 | 28.06 | 29.73 | 32.16 | 31.26 | 30.87 | 30.29 | 29.34 |
| 9 | 28.23 | 29.39 | 30.44 | 31.40 | 32.03 | 32.37 | 32.44 | 32.62 | 34.57 | 37.42 | 36.35 | 35.89 | 35.18 | 33.98 |
| 10 | 30.88 | 32.37 | 33.75 | 34.99 | 35.81 | 36.34 | 36.62 | 36.99 | 39.27 | 42.61 | 41.54 | 41.00 | 40.17 | 38.71 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 48.160 | 41.544 |
| SC2 | 0 | 8 | 32.958 | 28.059 |
| SC3 | -18 | 7 | 27.262 | 23.522 |
| SC4 | -25 | 6 | 22.053 | 19.103 |
| SC5 | -34 | 6 | 21.403 | 18.804 |
| A | 2815 mm |
|---|---|
| B | 950 mm |
| C | 1190 mm |
| F | 910 mm |
| E1 | 818 mm |
| E2 | 800 mm |
| E | 2435 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 2815 mm |
|---|---|
| Width | 950 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.