EA-291AG4-C04 C
121.69 kW
Defrost: None
Product code: EA-463FG4-C08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 51,459 m³/h |
|---|---|
| Air throw | 38 m |
| External surface | 668.3 m² |
| Inner volume | 135.0 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 627 kg |
| Quantity | 4 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 7,600 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 75.0 dB(A) |
|---|---|
| Sound power | 98.0 dB(A) |
| Energy class | D |
| Inlet | Ø54 |
|---|---|
| Outlet | Ø80 |
| EA-463FG4-C08 C | None |
|---|---|
| EA-463FG4-C08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 49.27 | 49.20 | 49.38 | 49.71 | 49.77 | 49.63 | 49.29 | 50.53 | 53.86 | 58.52 | 57.51 | 57.19 | 56.76 | 56.02 |
| 5 | 63.70 | 64.24 | 64.90 | 65.58 | 65.71 | 65.51 | 64.95 | 66.07 | 70.21 | 76.14 | 74.29 | 73.66 | 72.78 | 71.50 |
| 6 | 77.50 | 79.10 | 80.60 | 81.95 | 82.31 | 82.23 | 81.57 | 82.53 | 87.51 | 94.77 | 92.01 | 90.98 | 89.49 | 87.17 |
| 7 | 90.53 | 93.03 | 95.70 | 98.00 | 99.21 | 99.47 | 98.88 | 99.69 | 105.62 | 114.32 | 110.71 | 109.29 | 107.17 | 103.78 |
| 8 | 101.52 | 105.64 | 109.47 | 112.87 | 115.01 | 116.07 | 116.08 | 117.30 | 124.31 | 134.46 | 130.18 | 128.41 | 125.74 | 121.33 |
| 9 | 111.96 | 117.57 | 122.71 | 127.21 | 130.11 | 131.58 | 131.87 | 133.18 | 141.21 | 152.93 | 148.76 | 146.91 | 144.11 | 139.33 |
| 10 | 121.64 | 128.90 | 135.50 | 141.24 | 145.07 | 147.11 | 147.73 | 149.21 | 158.18 | 171.23 | 166.60 | 164.46 | 161.21 | not rated |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | 42.65 | 45.48 | 49.47 | 48.64 | 48.38 | 48.03 | 47.57 |
| 5 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | 58.41 | 63.40 | not rated | not rated | not rated | not rated |
| 6 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 7 | not rated | not rated | 79.65 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 8 | not rated | not rated | 91.95 | 94.01 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 9 | not rated | not rated | 103.71 | 106.66 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| 10 | not rated | not rated | 114.77 | 118.59 | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated | not rated |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 166.598 | — |
| SC2 | 0 | 8 | 117.295 | — |
| SC3 | -18 | 7 | 98.605 | — |
| SC4 | -25 | 6 | 80.597 | — |
| SC5 | -34 | 6 | 77.937 | — |
| A | 4415 mm |
|---|---|
| B | 1100 mm |
| C | 1190 mm |
| F | 1060 mm |
| G | 1135 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 4035 mm |
| D IN | 1 x Ø54 |
| D OUT | 1 x Ø80 |
| Length | 4415 mm |
|---|---|
| Width | 1100 mm |
| Height | 1190 mm |