EA-163ED4-C01 C
13.36 kW
Defrost: None
Product code: EA-630BE4-C05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,075 m³/h |
|---|---|
| Air throw | 6 m |
| External surface | 83.3 m² |
| Inner volume | 16.6 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 77 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | D |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EA-630BE4-C05 C | None |
|---|---|
| EA-630BE4-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.28 | 5.36 | 5.45 | 5.54 | 5.57 | 5.57 | 5.53 | 5.70 | 6.09 | 6.62 | 6.50 | 6.46 | 6.42 | 6.36 |
| 5 | 6.70 | 6.90 | 7.08 | 7.24 | 7.32 | 7.33 | 7.28 | 7.43 | 7.90 | 8.58 | 8.34 | 8.26 | 8.14 | 7.95 |
| 6 | 8.10 | 8.42 | 8.72 | 8.97 | 9.10 | 9.15 | 9.11 | 9.24 | 9.80 | 10.63 | 10.30 | 10.17 | 9.98 | 9.66 |
| 7 | 9.35 | 9.82 | 10.26 | 10.64 | 10.89 | 11.01 | 10.98 | 11.10 | 11.75 | 12.73 | 12.34 | 12.17 | 11.92 | 11.49 |
| 8 | 10.44 | 11.08 | 11.66 | 12.11 | 12.45 | 12.63 | 12.69 | 12.86 | 13.65 | 14.80 | 14.39 | 14.21 | 13.91 | 13.37 |
| 9 | 11.44 | 12.26 | 12.92 | 13.57 | 14.03 | 14.28 | 14.38 | 14.57 | 15.46 | 16.75 | 16.31 | 16.09 | 15.76 | 15.19 |
| 10 | 12.35 | 13.27 | 14.18 | 15.00 | 15.56 | 15.91 | 16.06 | 16.29 | 17.29 | 18.72 | 18.24 | 18.00 | 17.62 | 16.96 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 18.239 |
| SC2 | 0 | 8 | 12.862 |
| SC3 | -18 | 7 | 10.754 |
| SC4 | -25 | 6 | 8.718 |
| SC5 | -34 | 6 | 8.178 |
| A | 2557 mm |
|---|---|
| B | 567 mm |
| C | 445 mm |
| F | 395 mm |
| E1 | 385 mm |
| E2 | 367 mm |
| E | 2235 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 2407 mm |
|---|---|
| Width | 517 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.