Skip to Content

EK-S (Blast Freezers)

Application
Floor standing (blast freezer), Industrial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
10.62–107.60 kW
Fans
⌀500, ⌀630 mm
Max. working pressure
25 bar
EK-S (Blast Freezers)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EK-S = EK-S - blast freezer
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 50 = Ø500 mm63 = Ø630 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). E = 6 tube rowsG = 8 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 10=10.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 10 = Fin spacing about 10 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation B
  • H
    Fan data 08 = Ø630: 400V/3Ph/50Hz, 4-pole10 = Ø500: 400V/3Ph/50Hz, 4-pole13 = Ø630: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EK-S-150AE10-B10 C 10.62 kW 10.0 1 × ⌀500 7,730 None, Electric
Variants (2)
EK-S-150AG10-B10 C 13.10 kW 10.0 1 × ⌀500 7,362 None, Electric
Variants (2)
EK-S-163BE10-B08 C 19.60 kW 10.0 1 × ⌀630 16,155 None, Electric
Variants (2)
EK-S-250AE10-B10 C 20.93 kW 10.0 2 × ⌀500 15,469 None, Electric
Variants (2)
EK-S-163BE10-B13 C 21.69 kW 10.0 1 × ⌀630 18,121 None, Electric
Variants (2)
EK-S-163BG10-B08 C 24.43 kW 10.0 1 × ⌀630 15,379 None, Electric
Variants (2)
EK-S-250AG10-B10 C 26.18 kW 10.0 2 × ⌀500 14,724 None, Electric
Variants (2)
EK-S-163BG10-B13 C 27.41 kW 10.0 1 × ⌀630 17,427 None, Electric
Variants (2)
EK-S-350AE10-B10 C 31.83 kW 10.0 3 × ⌀500 23,191 None, Electric
Variants (2)
EK-S-350AG10-B10 C 39.16 kW 10.0 3 × ⌀500 22,078 None, Electric
Variants (2)
EK-S-263BE10-B08 C 39.45 kW 10.0 2 × ⌀630 32,307 None, Electric
Variants (2)
EK-S-450AE10-B10 C 42.44 kW 10.0 4 × ⌀500 30,935 None, Electric
Variants (2)
EK-S-263BE10-B13 C 43.45 kW 10.0 2 × ⌀630 36,241 None, Electric
Variants (2)
EK-S-263BG10-B08 C 48.84 kW 10.0 2 × ⌀630 30,758 None, Electric
Variants (2)
EK-S-450AG10-B10 C 52.35 kW 10.0 4 × ⌀500 29,447 None, Electric
Variants (2)
EK-S-263BG10-B13 C 54.60 kW 10.0 2 × ⌀630 34,856 None, Electric
Variants (2)
EK-S-363BE10-B08 C 59.17 kW 10.0 3 × ⌀630 48,461 None, Electric
Variants (2)
EK-S-363BE10-B13 C 65.21 kW 10.0 3 × ⌀630 54,361 None, Electric
Variants (2)
EK-S-363BG10-B08 C 73.26 kW 10.0 3 × ⌀630 46,138 None, Electric
Variants (2)
EK-S-463BE10-B08 C 78.60 kW 10.0 4 × ⌀630 64,534 None, Electric
Variants (2)
EK-S-363BG10-B13 C 82.03 kW 10.0 3 × ⌀630 52,283 None, Electric
Variants (2)
EK-S-463BE10-B13 C 84.63 kW 10.0 4 × ⌀630 72,414 None, Electric
Variants (2)
EK-S-463BG10-B08 C 97.97 kW 10.0 4 × ⌀630 61,450 None, Electric
Variants (2)
EK-S-463BG10-B13 C 107.60 kW 10.0 4 × ⌀630 69,655 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.