EA-240AG7-C01 C
11.93 kW
Defrost: None
Product code: EA-240AE4-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,181 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 58.6 m² |
| Inner volume | 12.4 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 73 kg |
| Quantity | 2 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 320 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 61.0 dB(A) |
|---|---|
| Sound power | 83.0 dB(A) |
| Energy class | C |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EA-240AE4-C01 C | None |
|---|---|
| EA-240AE4-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.58 | 4.63 | 4.69 | 4.75 | 4.77 | 4.75 | 4.71 | 4.87 | 5.20 | 5.65 | 5.56 | 5.53 | 5.51 | 5.42 |
| 5 | 5.89 | 6.05 | 6.20 | 6.32 | 6.38 | 6.37 | 6.32 | 6.46 | 6.87 | 7.46 | 7.26 | 7.20 | 7.11 | 6.99 |
| 6 | 7.18 | 7.47 | 7.74 | 7.95 | 8.07 | 8.08 | 8.03 | 8.15 | 8.65 | 9.38 | 9.08 | 8.97 | 8.81 | 8.56 |
| 7 | 8.32 | 8.75 | 9.13 | 9.47 | 9.69 | 9.80 | 9.79 | 9.91 | 10.50 | 11.39 | 11.02 | 10.88 | 10.66 | 10.30 |
| 8 | 9.31 | 9.89 | 10.42 | 10.81 | 11.12 | 11.29 | 11.34 | 11.50 | 12.21 | 13.25 | 12.90 | 12.75 | 12.51 | 12.11 |
| 9 | 10.21 | 10.86 | 11.56 | 12.15 | 12.56 | 12.79 | 12.89 | 13.08 | 13.88 | 15.05 | 14.66 | 14.48 | 14.20 | 13.72 |
| 10 | 11.03 | 11.87 | 12.71 | 13.45 | 13.97 | 14.29 | 14.44 | 14.66 | 15.57 | 16.88 | 16.45 | 16.24 | 15.92 | 15.35 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 16.449 |
| SC2 | 0 | 8 | 11.502 |
| SC3 | -18 | 7 | 9.573 |
| SC4 | -25 | 6 | 7.736 |
| SC5 | -34 | 6 | 7.255 |
| A | 1467 mm |
|---|---|
| B | 636 mm |
| C | 605 mm |
| F | 445 mm |
| E1 | 568 mm |
| E | 1135 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 1467 mm |
|---|---|
| Width | 636 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.