ED-430AE7-C25 C
10.52 kW
Defrost: None
Product code: ED-530AC7-C25 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,283 m³/h |
|---|---|
| Air throw | 9 m |
| External surface | 39.3 m² |
| Inner volume | 12.2 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 103 kg |
| Quantity | 5 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 600 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 47.0 dB(A) |
|---|---|
| Sound power | 69.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| ED-530AC7-C25 C | None |
|---|---|
| ED-530AC7-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.94 | 3.92 | 3.91 | 3.92 | 3.91 | 3.88 | 3.85 | 3.90 | 4.15 | 4.49 | 4.38 | 4.34 | 4.28 | 4.20 |
| 5 | 5.20 | 5.24 | 5.29 | 5.34 | 5.35 | 5.33 | 5.28 | 5.34 | 5.67 | 6.13 | 5.96 | 5.91 | 5.83 | 5.72 |
| 6 | 6.46 | 6.59 | 6.69 | 6.81 | 6.87 | 6.87 | 6.83 | 6.89 | 7.31 | 7.90 | 7.67 | 7.59 | 7.46 | 7.27 |
| 7 | 7.63 | 7.87 | 8.11 | 8.31 | 8.43 | 8.47 | 8.45 | 8.52 | 9.03 | 9.78 | 9.49 | 9.38 | 9.22 | 8.95 |
| 8 | 8.67 | 9.02 | 9.36 | 9.67 | 9.89 | 10.02 | 10.06 | 10.18 | 10.80 | 11.69 | 11.38 | 11.24 | 11.04 | 10.71 |
| 9 | 9.61 | 10.09 | 10.55 | 10.91 | 11.20 | 11.38 | 11.48 | 11.63 | 12.36 | 13.42 | 13.13 | 13.00 | 12.80 | 12.47 |
| 10 | 10.48 | 11.04 | 11.63 | 12.15 | 12.52 | 12.77 | 12.91 | 13.09 | 13.91 | 15.11 | 14.80 | 14.65 | 14.43 | 14.04 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 14.799 |
| SC2 | 0 | 8 | 10.178 |
| SC3 | -18 | 7 | 8.370 |
| SC4 | -25 | 6 | 6.692 |
| SC5 | -34 | 6 | 6.494 |
| A | 2848 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 2535 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 2848 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.