Skip to Content

EK-K (Blast Freezers)

Application
Floor standing (blast freezer), Industrial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
19.84–181.32 kW
Fans
⌀500, ⌀630 mm
Max. working pressure
25 bar
EK-K (Blast Freezers)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EK-K = EK-K - blast freezer
  • B
    Fan direction — Lowercase letter after the model code: Karyer "EK-K s (sucking fan), EK-K b (blowing fan)". b = Blowing fans = Sucking (suction) fan
  • C
    Number of fans — Number of fans (one digit).
  • D
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 50 = Ø500 mm63 = Ø630 mm
  • E
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • F
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). E = 6 tube rowsG = 8 tube rows
  • G
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 10=10.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 10 = Fin spacing about 10 mm
  • H
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation B
  • I
    Fan data 08 = Ø630: 400V/3Ph/50Hz, 4-pole10 = Ø500: 400V/3Ph/50Hz, 4-pole13 = Ø630: 400V/3Ph/50Hz, 4-pole22 = Ø500: 400V/3Ph/50Hz, 4-pole29 = Ø630: 400V/3Ph/50Hz, 4-pole31 = Ø630: 400V/3Ph/50Hz, 4-pole
  • K
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EK-K-s-250AE10-B10 C 19.84 kW 10.0 2 × ⌀500 14,987 None, Electric
Variants (2)
EK-K-b-250AE10-B22 C 20.06 kW 10.0 2 × ⌀500 15,198 None, Electric
Variants (2)
EK-K-s-250AG10-B10 C 24.45 kW 10.0 2 × ⌀500 14,174 None, Electric
Variants (2)
EK-K-b-250AG10-B22 C 24.74 kW 10.0 2 × ⌀500 14,367 None, Electric
Variants (2)
EK-K-b-263BE10-B29 C 33.48 kW 10.0 2 × ⌀630 29,740 None, Electric
Variants (2)
EK-K-s-263BE10-B08 C 33.49 kW 10.0 2 × ⌀630 29,740 None, Electric
Variants (2)
EK-K-b-263BE10-B31 C 36.51 kW 10.0 2 × ⌀630 33,915 None, Electric
Variants (2)
EK-K-s-263BE10-B13 C 36.51 kW 10.0 2 × ⌀630 33,915 None, Electric
Variants (2)
EK-K-s-450AE10-B10 C 39.68 kW 10.0 4 × ⌀500 29,974 None, Electric
Variants (2)
EK-K-b-450AE10-B22 C 40.11 kW 10.0 4 × ⌀500 30,397 None, Electric
Variants (2)
EK-K-b-263BG10-B29 C 41.13 kW 10.0 2 × ⌀630 27,612 None, Electric
Variants (2)
EK-K-s-263BG10-B08 C 41.14 kW 10.0 2 × ⌀630 27,612 None, Electric
Variants (2)
EK-K-b-263BG10-B31 C 46.68 kW 10.0 2 × ⌀630 32,033 None, Electric
Variants (2)
EK-K-s-263BG10-B13 C 46.68 kW 10.0 2 × ⌀630 32,033 None, Electric
Variants (2)
EK-K-s-450AG10-B10 C 48.89 kW 10.0 4 × ⌀500 28,348 None, Electric
Variants (2)
EK-K-b-450AG10-B22 C 49.46 kW 10.0 4 × ⌀500 28,734 None, Electric
Variants (2)
EK-K-s-650AE10-B10 C 59.69 kW 10.0 6 × ⌀500 44,934 None, Electric
Variants (2)
EK-K-b-650AE10-B22 C 60.30 kW 10.0 6 × ⌀500 45,570 None, Electric
Variants (2)
EK-K-b-463BE10-B29 C 66.98 kW 10.0 4 × ⌀630 59,481 None, Electric
Variants (2)
EK-K-s-463BE10-B08 C 66.98 kW 10.0 4 × ⌀630 59,481 None, Electric
Variants (2)
EK-K-s-650AG10-B10 C 73.11 kW 10.0 6 × ⌀500 42,504 None, Electric
Variants (2)
EK-K-b-463BE10-B31 C 73.16 kW 10.0 4 × ⌀630 67,829 None, Electric
Variants (2)
EK-K-s-463BE10-B13 C 73.16 kW 10.0 4 × ⌀630 67,829 None, Electric
Variants (2)
EK-K-b-650AG10-B22 C 73.92 kW 10.0 6 × ⌀500 43,079 None, Electric
Variants (2)
EK-K-s-850AE10-B10 C 79.34 kW 10.0 8 × ⌀500 59,948 None, Electric
Variants (2)
EK-K-b-850AE10-B22 C 80.19 kW 10.0 8 × ⌀500 60,794 None, Electric
Variants (2)
EK-K-b-463BG10-B29 C 82.25 kW 10.0 4 × ⌀630 55,225 None, Electric
Variants (2)
EK-K-s-463BG10-B08 C 82.25 kW 10.0 4 × ⌀630 55,225 None, Electric
Variants (2)
EK-K-b-463BG10-B31 C 92.93 kW 10.0 4 × ⌀630 64,072 None, Electric
Variants (2)
EK-K-s-463BG10-B13 C 92.93 kW 10.0 4 × ⌀630 64,072 None, Electric
Variants (2)
EK-K-s-850AG10-B10 C 97.76 kW 10.0 8 × ⌀500 56,697 None, Electric
Variants (2)
EK-K-b-850AG10-B22 C 98.89 kW 10.0 8 × ⌀500 57,468 None, Electric
Variants (2)
EK-K-b-663BE10-B29 C 100.45 kW 10.0 6 × ⌀630 89,222 None, Electric
Variants (2)
EK-K-s-663BE10-B08 C 100.45 kW 10.0 6 × ⌀630 89,222 None, Electric
Variants (2)
EK-K-b-663BE10-B31 C 109.86 kW 10.0 6 × ⌀630 101,742 None, Electric
Variants (2)
EK-K-s-663BE10-B13 C 109.86 kW 10.0 6 × ⌀630 101,742 None, Electric
Variants (2)
EK-K-b-663BG10-B29 C 123.37 kW 10.0 6 × ⌀630 82,838 None, Electric
Variants (2)
EK-K-s-663BG10-B08 C 123.37 kW 10.0 6 × ⌀630 82,838 None, Electric
Variants (2)
EK-K-b-863BE10-B29 C 131.60 kW 10.0 8 × ⌀630 118,705 None, Electric
Variants (2)
EK-K-s-863BE10-B08 C 131.60 kW 10.0 8 × ⌀630 118,705 None, Electric
Variants (2)
EK-K-b-663BG10-B31 C 139.49 kW 10.0 6 × ⌀630 96,107 None, Electric
Variants (2)
EK-K-s-663BG10-B13 C 139.49 kW 10.0 6 × ⌀630 96,107 None, Electric
Variants (2)
EK-K-b-863BE10-B31 C 143.87 kW 10.0 8 × ⌀630 135,429 None, Electric
Variants (2)
EK-K-s-863BE10-B13 C 143.87 kW 10.0 8 × ⌀630 135,429 None, Electric
Variants (2)
EK-K-b-863BG10-B29 C 163.97 kW 10.0 8 × ⌀630 110,241 None, Electric
Variants (2)
EK-K-s-863BG10-B08 C 163.97 kW 10.0 8 × ⌀630 110,241 None, Electric
Variants (2)
EK-K-b-863BG10-B31 C 181.32 kW 10.0 8 × ⌀630 127,958 None, Electric
Variants (2)
EK-K-s-863BG10-B13 C 181.32 kW 10.0 8 × ⌀630 127,958 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.