- Catalogue
- Dry coolers
- BE (Dry)
BE (Dry)
- Refrigerants
- ETHYLENE GLYCOL 30%, PROPYLENE GLYCOL 30%, WATER
- Capacity
- 69.30–1727.54 kW
- Fans
- ⌀800, ⌀910 mm
- Max. working pressure
- 10 bar
Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series BE = BE = V-type dry cooler.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| BE-180DB5-B01 C | 69.30 kW | 1 × ⌀800 | 22,400 |
Variants (1)
|
| BE-180DB1-B01 C | 75.48 kW | 1 × ⌀800 | 22,322 |
Variants (1)
|
| BE-180DC5-B01 C | 80.52 kW | 1 × ⌀800 | 22,173 |
Variants (1)
|
| BE-180CB5-B01 C | 82.80 kW | 1 × ⌀800 | 22,654 |
Variants (1)
|
| BE-191DB5-B04 C | 84.79 kW | 1 × ⌀910 | 29,695 |
Variants (1)
|
| BE-t-180HB5-B01 C | 84.92 kW | 1 × ⌀800 | 22,236 |
Variants (1)
|
| BE-180DC1-B01 C | 86.06 kW | 1 × ⌀800 | 22,072 |
Variants (1)
|
| BE-180DD5-B01 C | 87.51 kW | 1 × ⌀800 | 21,951 |
Variants (1)
|
| BE-180CB1-B01 C | 88.60 kW | 1 × ⌀800 | 22,602 |
Variants (1)
|
| BE-t-180HB1-B01 C | 91.24 kW | 1 × ⌀800 | 22,141 |
Variants (1)
|
| BE-180DD1-B01 C | 92.15 kW | 1 × ⌀800 | 21,829 |
Variants (1)
|
| BE-180CC5-B01 C | 92.20 kW | 1 × ⌀800 | 22,503 |
Variants (1)
|
| BE-191DB1-B04 C | 92.93 kW | 1 × ⌀910 | 29,550 |
Variants (1)
|
| BE-t-180HC5-B01 C | 96.32 kW | 1 × ⌀800 | 21,960 |
Variants (1)
|
| BE-180CC1-B01 C | 96.86 kW | 1 × ⌀800 | 22,436 |
Variants (1)
|
| BE-191DC5-B04 C | 98.37 kW | 1 × ⌀910 | 29,275 |
Variants (1)
|
| BE-180CD5-B01 C | 98.62 kW | 1 × ⌀800 | 22,356 |
Variants (1)
|
| BE-t-180HC1-B01 C | 101.47 kW | 1 × ⌀800 | 21,838 |
Variants (1)
|
| BE-180CD1-B01 C | 102.11 kW | 1 × ⌀800 | 22,273 |
Variants (1)
|
| BE-191CB5-B04 C | 102.63 kW | 1 × ⌀910 | 30,158 |
Variants (1)
|
| BE-t-191HB5-B04 C | 104.24 kW | 1 × ⌀910 | 29,391 |
Variants (1)
|
| BE-191DC1-B04 C | 105.90 kW | 1 × ⌀910 | 29,090 |
Variants (1)
|
| BE-191DD5-B04 C | 109.16 kW | 1 × ⌀910 | 28,872 |
Variants (1)
|
| BE-191CB1-B04 C | 110.78 kW | 1 × ⌀910 | 30,071 |
Variants (1)
|
| BE-t-191HB1-B04 C | 112.83 kW | 1 × ⌀910 | 29,217 |
Variants (1)
|
| BE-280BB5-B01 C | 115.15 kW | 2 × ⌀800 | 43,100 |
Variants (1)
|
| BE-191DD1-B04 C | 115.69 kW | 1 × ⌀910 | 28,650 |
Variants (1)
|
| BE-191CC5-B04 C | 115.89 kW | 1 × ⌀910 | 29,887 |
Variants (1)
|
| BE-t-191HC5-B04 C | 118.32 kW | 1 × ⌀910 | 28,888 |
Variants (1)
|
| BE-191CC1-B04 C | 122.73 kW | 1 × ⌀910 | 29,761 |
Variants (1)
|
| BE-191CD5-B04 C | 125.28 kW | 1 × ⌀910 | 29,613 |
Variants (1)
|
| BE-t-191HC1-B04 C | 125.47 kW | 1 × ⌀910 | 28,668 |
Variants (1)
|
| BE-280BB1-B01 C | 126.58 kW | 2 × ⌀800 | 42,784 |
Variants (1)
|
| BE-2x180DB5-B01C C | 127.33 kW | 2 × ⌀800 | 44,066 |
Variants (1) |
| BE-191CD1-B04 C | 130.66 kW | 1 × ⌀910 | 29,459 |
Variants (1)
|
| BE-280AB5-B01 C | 130.91 kW | 2 × ⌀800 | 43,397 |
Variants (1)
|
| BE-2x180DB5-B01T C | 134.79 kW | 2 × ⌀800 | 44,583 |
Variants (1) |
| BE-280BC5-B01 C | 136.98 kW | 2 × ⌀800 | 42,152 |
Variants (1)
|
| BE-2x180DB1-B01C C | 139.39 kW | 2 × ⌀800 | 43,836 |
Variants (1) |
| BE-280DB5-B01 C | 140.27 kW | 2 × ⌀800 | 44,800 |
Variants (1)
|
| BE-t-280GB5-B01 C | 141.68 kW | 2 × ⌀800 | 42,431 |
Variants (1)
|
| BE-280AB1-B01 C | 142.54 kW | 2 × ⌀800 | 43,104 |
Variants (1)
|
| BE-291BB5-B04 C | 143.71 kW | 2 × ⌀910 | 57,005 |
Variants (1)
|
| BE-2x180DB1-B01T C | 147.08 kW | 2 × ⌀800 | 44,405 |
Variants (1) |
| BE-2x180DC5-B01C C | 147.25 kW | 2 × ⌀800 | 43,402 |
Variants (1) |
| BE-280BC1-B01 C | 147.65 kW | 2 × ⌀800 | 41,709 |
Variants (1)
|
| BE-280AC5-B01 C | 149.84 kW | 2 × ⌀800 | 42,561 |
Variants (1)
|
| BE-280BD5-B01 C | 150.13 kW | 2 × ⌀800 | 41,195 |
Variants (1)
|
| BE-2x191DB5-C04C C | 152.04 kW | 2 × ⌀910 | 57,841 |
Variants (1) |
| BE-280DB1-B01 C | 152.74 kW | 2 × ⌀800 | 44,644 |
Variants (1)
|
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
Downloads
- BE-180DB5-B01 C — product datasheet (PDF)
- BE-180DB1-B01 C — product datasheet (PDF)
- BE-180DC5-B01 C — product datasheet (PDF)
- BE-180CB5-B01 C — product datasheet (PDF)
- BE-191DB5-B04 C — product datasheet (PDF)
- BE-t-180HB5-B01 C — product datasheet (PDF)
- BE-180DC1-B01 C — product datasheet (PDF)
- BE-180DD5-B01 C — product datasheet (PDF)
- BE-180CB1-B01 C — product datasheet (PDF)
- BE-t-180HB1-B01 C — product datasheet (PDF)
- BE-180DD1-B01 C — product datasheet (PDF)
- BE-180CC5-B01 C — product datasheet (PDF)
- BE-191DB1-B04 C — product datasheet (PDF)
- BE-t-180HC5-B01 C — product datasheet (PDF)
- BE-180CC1-B01 C — product datasheet (PDF)
- BE-191DC5-B04 C — product datasheet (PDF)
- BE-180CD5-B01 C — product datasheet (PDF)
- BE-t-180HC1-B01 C — product datasheet (PDF)
- BE-180CD1-B01 C — product datasheet (PDF)
- BE-191CB5-B04 C — product datasheet (PDF)
- BE-t-191HB5-B04 C — product datasheet (PDF)
- BE-191DC1-B04 C — product datasheet (PDF)
- BE-191DD5-B04 C — product datasheet (PDF)
- BE-191CB1-B04 C — product datasheet (PDF)
- BE-t-191HB1-B04 C — product datasheet (PDF)
- BE-280BB5-B01 C — product datasheet (PDF)
- BE-191DD1-B04 C — product datasheet (PDF)
- BE-191CC5-B04 C — product datasheet (PDF)
- BE-t-191HC5-B04 C — product datasheet (PDF)
- BE-191CC1-B04 C — product datasheet (PDF)
- BE-191CD5-B04 C — product datasheet (PDF)
- BE-t-191HC1-B04 C — product datasheet (PDF)
- BE-280BB1-B01 C — product datasheet (PDF)
- BE-2x180DB5-B01C C — product datasheet (PDF)
- BE-191CD1-B04 C — product datasheet (PDF)
- BE-280AB5-B01 C — product datasheet (PDF)
- BE-2x180DB5-B01T C — product datasheet (PDF)
- BE-280BC5-B01 C — product datasheet (PDF)
- BE-2x180DB1-B01C C — product datasheet (PDF)
- BE-280DB5-B01 C — product datasheet (PDF)
- BE-t-280GB5-B01 C — product datasheet (PDF)
- BE-280AB1-B01 C — product datasheet (PDF)
- BE-291BB5-B04 C — product datasheet (PDF)
- BE-2x180DB1-B01T C — product datasheet (PDF)
- BE-2x180DC5-B01C C — product datasheet (PDF)
- BE-280BC1-B01 C — product datasheet (PDF)
- BE-280AC5-B01 C — product datasheet (PDF)
- BE-280BD5-B01 C — product datasheet (PDF)
- BE-2x191DB5-C04C C — product datasheet (PDF)
- BE-280DB1-B01 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.