Model nomenclature
How to read the model codes of this series, with an example.
-
A
Series BE = BE = V-type dry cooler.
-
B
Fin type (optional "t") — = absent: standard corrugated finst = t: louvered fins (high-efficiency fin surface)
-
C
Fan rows (optional "Nx") — Catalogue: "Fan Row no." (number before x/X). — = absent: 1 fan row2x = 2 fan rows
-
D
Number of fans per row — Digit 1-9; total fans = fan rows x this digit.
-
E
Fan diameter — Two digits = diameter / 10 (91 = Ø910). 80 = Ø800 mm91 = Ø910 mm
-
G
Coil tube rows (2nd dimensional letter) B = 3 tube rowsC = 4 tube rowsD = 5 tube rows
-
H
Fin spacing — Catalogue fin-spacing code. 1 = 2.1 mm5 = 2.5 mm
-
I
Generation code — Catalogue: "Generation Code". B = generation BC = generation C
-
J
Fan data (fan motor code) — Catalogue: "Fan Data". Two digits select the fan motor (supply, poles); the meaning is series-specific. 01 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)04 = three-phase 400 V 50 Hz, 6-pole AC fan (in this series)
-
K
Delivery version (optional) — = absent: standardC = C: container delivery versionT = T: truck delivery version
| Model | Heat rejection [kW] i Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 % | Fans | Air flow [m³/h] | Variants |
|---|---|---|---|---|
| BE-2x180CB5-B01C C | 153.59 kW | 2 × ⌀800 | 44,796 |
Variants (1) |
| BE-t-280GB1-B01 C | 153.74 kW | 2 × ⌀800 | 42,012 |
Variants (1)
|
| BE-t-2x180HB5-B01C C | 156.45 kW | 2 × ⌀800 | 43,584 |
Variants (1) |
| BE-291AB5-B04 C | 156.54 kW | 2 × ⌀910 | 56,832 |
Variants (1)
|
| BE-2x180DC5-B01T C | 157.10 kW | 2 × ⌀800 | 44,064 |
Variants (1) |
| BE-2x180DC1-B01C C | 158.31 kW | 2 × ⌀800 | 43,111 |
Variants (1) |
| BE-291BB1-B04 C | 158.55 kW | 2 × ⌀910 | 56,498 |
Variants (1)
|
| BE-280BD1-B01 C | 159.24 kW | 2 × ⌀800 | 40,681 |
Variants (1)
|
| BE-280AC1-B01 C | 159.94 kW | 2 × ⌀800 | 42,157 |
Variants (1)
|
| BE-2x180CB5-B01T C | 160.47 kW | 2 × ⌀800 | 45,112 |
Variants (1) |
| BE-280DC5-B01 C | 160.97 kW | 2 × ⌀800 | 44,346 |
Variants (1)
|
| BE-2x180DD5-B01C C | 163.14 kW | 2 × ⌀800 | 42,770 |
Variants (1) |
| BE-280AD5-B01 C | 164.22 kW | 2 × ⌀800 | 41,682 |
Variants (1)
|
| BE-2x191DB5-B04T C | 164.28 kW | 2 × ⌀910 | 58,987 |
Variants (1) |
| BE-t-280GC5-B01 C | 164.41 kW | 2 × ⌀800 | 41,232 |
Variants (1)
|
| BE-t-2x180HB5-B01T C | 165.33 kW | 2 × ⌀800 | 44,208 |
Variants (1) |
| BE-280CB5-B01 C | 165.51 kW | 2 × ⌀800 | 45,308 |
Variants (1)
|
| BE-2x180CB1-B01C C | 165.54 kW | 2 × ⌀800 | 44,639 |
Variants (1) |
| BE-2x191DB1-C04C C | 167.46 kW | 2 × ⌀910 | 57,406 |
Variants (1) |
| BE-2x180DC1-B01T C | 168.23 kW | 2 × ⌀800 | 43,833 |
Variants (1) |
| BE-291BC5-B04 C | 168.50 kW | 2 × ⌀910 | 55,589 |
Variants (1)
|
| BE-t-2x180HB1-B01C C | 169.13 kW | 2 × ⌀800 | 43,310 |
Variants (1) |
| BE-291DB5-B04 C | 169.46 kW | 2 × ⌀910 | 59,389 |
Variants (1)
|
| BE-2x180DD5-B01T C | 171.09 kW | 2 × ⌀800 | 43,561 |
Variants (1) |
| BE-291AB1-B04 C | 171.52 kW | 2 × ⌀910 | 56,307 |
Variants (1)
|
| BE-t-280HB5-B01 C | 171.82 kW | 2 × ⌀800 | 44,472 |
Variants (1)
|
| BE-280DC1-B01 C | 172.05 kW | 2 × ⌀800 | 44,143 |
Variants (1)
|
| BE-2x180CB1-B01T C | 172.28 kW | 2 × ⌀800 | 44,987 |
Variants (1) |
| BE-280AD1-B01 C | 172.36 kW | 2 × ⌀800 | 41,200 |
Variants (1)
|
| BE-2x180DD1-B01C C | 172.59 kW | 2 × ⌀800 | 42,414 |
Variants (1) |
| BE-2x180CC5-B01C C | 173.01 kW | 2 × ⌀800 | 44,341 |
Variants (1) |
| BE-380BB5-B01 C | 174.06 kW | 3 × ⌀800 | 64,650 |
Variants (1)
|
| BE-t-280GC1-B01 C | 174.69 kW | 2 × ⌀800 | 40,721 |
Variants (1)
|
| BE-280DD5-B01 C | 174.95 kW | 2 × ⌀800 | 43,903 |
Variants (1)
|
| BE-t-2x180HC5-B01C C | 176.93 kW | 2 × ⌀800 | 42,795 |
Variants (1) |
| BE-t-291GB5-B04 C | 176.97 kW | 2 × ⌀910 | 55,952 |
Variants (1)
|
| BE-280CB1-B01 C | 177.12 kW | 2 × ⌀800 | 45,204 |
Variants (1)
|
| BE-2x191DC5-C04C C | 177.60 kW | 2 × ⌀910 | 56,590 |
Variants (1) |
| BE-t-2x180HB1-B01T C | 178.16 kW | 2 × ⌀800 | 43,991 |
Variants (1) |
| BE-2x180CC5-B01T C | 179.63 kW | 2 × ⌀800 | 44,751 |
Variants (1) |
| BE-2x191DB1-B04T C | 180.35 kW | 2 × ⌀910 | 58,658 |
Variants (1) |
| BE-2x180DD1-B01T C | 180.50 kW | 2 × ⌀800 | 43,285 |
Variants (1) |
| BE-291AC5-B04 C | 181.10 kW | 2 × ⌀910 | 55,393 |
Variants (1)
|
| BE-2x191CB5-C04C C | 182.63 kW | 2 × ⌀910 | 59,195 |
Variants (1) |
| BE-291BC1-B04 C | 182.72 kW | 2 × ⌀910 | 55,016 |
Variants (1)
|
| BE-2x180CC1-B01C C | 182.99 kW | 2 × ⌀800 | 44,136 |
Variants (1) |
| BE-280DD1-B01 C | 184.23 kW | 2 × ⌀800 | 43,657 |
Variants (1)
|
| BE-280CC5-B01 C | 184.32 kW | 2 × ⌀800 | 45,007 |
Variants (1)
|
| BE-t-280HB1-B01 C | 184.63 kW | 2 × ⌀800 | 44,282 |
Variants (1)
|
| BE-291DB1-B04 C | 185.74 kW | 2 × ⌀910 | 59,100 |
Variants (1)
|
Nominal conditions: water 40 → 35 °C, air inlet 25 °C, relative humidity 50 %
Downloads
- BE-2x180CB5-B01C C — product datasheet (PDF)
- BE-t-280GB1-B01 C — product datasheet (PDF)
- BE-t-2x180HB5-B01C C — product datasheet (PDF)
- BE-291AB5-B04 C — product datasheet (PDF)
- BE-2x180DC5-B01T C — product datasheet (PDF)
- BE-2x180DC1-B01C C — product datasheet (PDF)
- BE-291BB1-B04 C — product datasheet (PDF)
- BE-280BD1-B01 C — product datasheet (PDF)
- BE-280AC1-B01 C — product datasheet (PDF)
- BE-2x180CB5-B01T C — product datasheet (PDF)
- BE-280DC5-B01 C — product datasheet (PDF)
- BE-2x180DD5-B01C C — product datasheet (PDF)
- BE-280AD5-B01 C — product datasheet (PDF)
- BE-2x191DB5-B04T C — product datasheet (PDF)
- BE-t-280GC5-B01 C — product datasheet (PDF)
- BE-t-2x180HB5-B01T C — product datasheet (PDF)
- BE-280CB5-B01 C — product datasheet (PDF)
- BE-2x180CB1-B01C C — product datasheet (PDF)
- BE-2x191DB1-C04C C — product datasheet (PDF)
- BE-2x180DC1-B01T C — product datasheet (PDF)
- BE-291BC5-B04 C — product datasheet (PDF)
- BE-t-2x180HB1-B01C C — product datasheet (PDF)
- BE-291DB5-B04 C — product datasheet (PDF)
- BE-2x180DD5-B01T C — product datasheet (PDF)
- BE-291AB1-B04 C — product datasheet (PDF)
- BE-t-280HB5-B01 C — product datasheet (PDF)
- BE-280DC1-B01 C — product datasheet (PDF)
- BE-2x180CB1-B01T C — product datasheet (PDF)
- BE-280AD1-B01 C — product datasheet (PDF)
- BE-2x180DD1-B01C C — product datasheet (PDF)
- BE-2x180CC5-B01C C — product datasheet (PDF)
- BE-380BB5-B01 C — product datasheet (PDF)
- BE-t-280GC1-B01 C — product datasheet (PDF)
- BE-280DD5-B01 C — product datasheet (PDF)
- BE-t-2x180HC5-B01C C — product datasheet (PDF)
- BE-t-291GB5-B04 C — product datasheet (PDF)
- BE-280CB1-B01 C — product datasheet (PDF)
- BE-2x191DC5-C04C C — product datasheet (PDF)
- BE-t-2x180HB1-B01T C — product datasheet (PDF)
- BE-2x180CC5-B01T C — product datasheet (PDF)
- BE-2x191DB1-B04T C — product datasheet (PDF)
- BE-2x180DD1-B01T C — product datasheet (PDF)
- BE-291AC5-B04 C — product datasheet (PDF)
- BE-2x191CB5-C04C C — product datasheet (PDF)
- BE-291BC1-B04 C — product datasheet (PDF)
- BE-2x180CC1-B01C C — product datasheet (PDF)
- BE-280DD1-B01 C — product datasheet (PDF)
- BE-280CC5-B01 C — product datasheet (PDF)
- BE-t-280HB1-B01 C — product datasheet (PDF)
- BE-291DB1-B04 C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.