Compressor rack BSCR-3P-ZB66

Compressor rack BSCR-3P-ZB66
Illustrative photo

Producer: Albassem BRI · Line: Sphinx CompactRack MT

Product code: BSCR-3P-ZB66

Refrigerating capacity i
44.10 kW
Absorbed power
21.20 kW
COP
2.08
Compressors
3 × scroll compressors
Receiver
60 l

Nominal conditions: evaporating -10 °C, condensing 45 °C (dew points), superheat 10 K, subcooling 3 K; refrigerant R404A where rated.

Model nomenclature

How to read the code of this model.

  • A
    Series: BSCR — Sphinx CompactRack
  • B
    Number of compressors: 3 — Number of identical compressors on the rack (2 to 4).
  • C
    Application: P — Medium / high temperature
  • D
    Compressor model: ZB66 — Model of the compressors fitted (all compressors of a rack are the same model); an 'EVI' tail marks enhanced vapour injection.

Data

Rack
ApplicationMedium temperature (MT)
Compressors3 × scroll compressors
Liquid receiver 60 l
Net weight 408 kg
Electrical
Max. current 46.5 A
Starting current 142.5 A
Connections
Suction 2"1/8
Liquid 1"1/8
Discharge 1"1/8
Liquid set
L / W / H 666/402/1366 mm
Weight 80 kg

Performance

Evaporating temperature -50…5 °C, condensing temperature 20…55 °C (dew points); superheat 10 K, subcooling 3 K.

R404A, evaporating -10 °C, condensing 45 °C (dew points; superheat 10 K, subcooling 3 K)

Refrigerating capacity
44.10 kW
Absorbed power
21.20 kW
COP
2.08
Current
40.3 A
Heat rejection
65.30 kW

Heat rejection = refrigerating capacity + absorbed power. COP = refrigerating capacity / absorbed power.

Standard points

Te [°C] Tc [°C] Refrigerating capacity [kW] Absorbed power [kW] COP Current [A]
-10 40 48.40 19.10 2.53 37.7
-10 45 44.10 21.20 2.08 40.3

Evaporating × condensing temperature (dew points)

R404A; rows: condensing temperature Tc [°C]; columns: evaporating temperature Te [°C]. The highlighted cell is the nominal point. "—": outside the compressors' operating envelope.

Capacity [kW]

Capacity [kW]: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -25-20-15-10-505
20 33.50 41.80 51.70 63.40 77.00 92.70 not rated
25 31.50 39.40 48.80 59.90 72.80 87.60 104.60
30 29.40 36.90 45.80 56.20 68.40 82.40 98.50
35 27.10 34.20 42.60 52.40 63.80 77.00 92.20
40 24.80 31.40 39.20 48.40 59.00 71.40 85.60
45 22.30 28.40 35.70 44.10 54.10 65.60 78.90
50 not rated 25.30 32.00 39.70 48.90 59.50 71.90
55 not rated 22.00 28.10 35.10 43.50 53.20 64.60

Power [kW]

Power [kW]: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -25-20-15-10-505
20 12.30 12.40 12.60 12.80 13.10 13.50 not rated
25 13.60 13.80 13.90 14.10 14.30 14.70 15.30
30 15.10 15.30 15.40 15.50 15.70 16.00 16.50
35 16.70 17.00 17.10 17.20 17.30 17.60 17.90
40 18.70 18.90 19.00 19.10 19.20 19.30 19.60
45 20.90 21.10 21.20 21.20 21.30 21.30 21.50
50 not rated 23.60 23.70 23.70 23.70 23.70 23.80
55 not rated 26.50 26.60 26.50 26.40 26.40 26.30

COP

COP: Evaporating × condensing temperature (dew points)
Tc \ Te [°C] -25-20-15-10-505
20 2.72 3.37 4.10 4.95 5.88 6.87 not rated
25 2.32 2.86 3.51 4.25 5.09 5.96 6.84
30 1.95 2.41 2.97 3.63 4.36 5.15 5.97
35 1.62 2.01 2.49 3.05 3.69 4.38 5.15
40 1.33 1.66 2.06 2.53 3.07 3.70 4.37
45 1.07 1.35 1.68 2.08 2.54 3.08 3.67
50 not rated 1.07 1.35 1.68 2.06 2.51 3.02
55 not rated 0.83 1.06 1.32 1.65 2.02 2.46

Dimensions

Dimension drawing of BSCR-3P-ZB66
Dimension drawing
Dimensions as drawn
L 1785 mm
P 825 mm
H 1255 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.