EA-DA-x-135BE7-B21 C
3.00 kW
Defrost: None
Product code: EA-DA-135BE7-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,041 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 12.7 m² |
| Inner volume | 4.7 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 49 kg |
| Quantity | 1 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 165 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | C |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø15,9 |
| EA-DA-135BE7-C21 C | None |
|---|---|
| EA-DA-135BE7-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 1.30 | 1.33 | 1.37 | 1.39 | 1.40 | 1.39 | 1.38 | 1.41 | 1.51 | 1.63 | 1.59 | 1.58 | 1.56 | 1.52 |
| 5 | 1.64 | 1.73 | 1.80 | 1.85 | 1.88 | 1.88 | 1.87 | 1.90 | 2.02 | 2.19 | 2.12 | 2.10 | 2.07 | 2.02 |
| 6 | 1.96 | 2.10 | 2.21 | 2.31 | 2.37 | 2.39 | 2.38 | 2.42 | 2.56 | 2.77 | 2.68 | 2.65 | 2.60 | 2.51 |
| 7 | 2.28 | 2.46 | 2.63 | 2.77 | 2.86 | 2.91 | 2.91 | 2.95 | 3.13 | 3.39 | 3.28 | 3.23 | 3.16 | 3.04 |
| 8 | ≈ 2.53 | 2.77 | 2.99 | 3.17 | 3.31 | 3.37 | 3.40 | 3.46 | 3.68 | 3.99 | 3.87 | 3.82 | 3.74 | 3.59 |
| 9 | ≈ 2.76 | 3.04 | 3.31 | 3.52 | 3.68 | 3.80 | 3.86 | 3.93 | 4.18 | 4.54 | 4.43 | 4.38 | 4.29 | 4.14 |
| 10 | ≈ 2.77 | ≈ 3.29 | 3.56 | 3.86 | 4.07 | 4.22 | 4.31 | 4.40 | 4.68 | 5.08 | 4.97 | 4.91 | 4.81 | 4.64 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 4.968 |
| SC2 | 0 | 8 | 3.462 |
| SC3 | -18 | 7 | 2.810 |
| SC4 | -25 | 6 | 2.213 |
| SC5 | -34 | 6 | 1.993 |
| A | 957 mm |
|---|---|
| B | 730 mm |
| C | 530 mm |
| F | 560 mm |
| E | 535 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø15,9 |
| Length | 957 mm |
|---|---|
| Width | 730 mm |
| Height | 530 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.