EA-463EE10-C01 C
46.44 kW
Defrost: Electric
Product code: EA-463EC4-C06 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 34,348 m³/h |
|---|---|
| Air throw | 24 m |
| External surface | 267.0 m² |
| Inner volume | 53.0 dm³ |
| Fin spacing | 4.6 mm |
| Fin material | Aluminium |
| Net weight | 329 kg |
| Quantity | 4 |
|---|---|
| Diameter | 630 mm |
| Speed | 890 rpm |
| Power | 2,400 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 56.0 dB(A) |
|---|---|
| Sound power | 79.1 dB(A) |
| Energy class | D |
| Inlet | Ø35 |
|---|---|
| Outlet | Ø54 |
| EA-463EC4-C06 C | None |
|---|---|
| EA-463EC4-C06 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 17.73 | 17.82 | 17.90 | 18.06 | 18.10 | 18.07 | 17.99 | 18.31 | 19.41 | 21.02 | 20.59 | 20.43 | 20.21 | 19.88 |
| 5 | 23.00 | 23.50 | 23.94 | 24.31 | 24.46 | 24.45 | 24.31 | 24.60 | 26.13 | 28.27 | 27.63 | 27.40 | 27.08 | 26.62 |
| 6 | 28.01 | 28.92 | 29.85 | 30.63 | 31.05 | 31.20 | 31.13 | 31.44 | 33.36 | 36.11 | 35.19 | 34.85 | 34.36 | 33.62 |
| 7 | 32.20 | 33.76 | 35.18 | 36.44 | 37.27 | 37.78 | 38.03 | 38.53 | 40.96 | 44.47 | 43.32 | 42.88 | 42.22 | 41.19 |
| 8 | 36.02 | 38.18 | 40.14 | 41.86 | 43.03 | 43.77 | 44.16 | 44.74 | 47.55 | 51.67 | 50.58 | 50.15 | 49.49 | 48.41 |
| 9 | 39.52 | 42.34 | 44.90 | 47.15 | 48.73 | 49.76 | 50.34 | 51.03 | 54.24 | 58.96 | 57.72 | 57.21 | 56.42 | 55.12 |
| 10 | ≈ 42.69 | 46.20 | 49.44 | 52.28 | 54.33 | 55.70 | 56.52 | 57.35 | 60.98 | 66.31 | 64.96 | 64.37 | 63.47 | 61.94 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 15.65 | 15.65 | 15.73 | 15.84 | 15.89 | 15.88 | 15.84 | 16.10 | 17.13 | 18.58 | 18.23 | 18.11 | 17.93 | 17.66 |
| 5 | 20.38 | 20.61 | 20.86 | 21.11 | 21.18 | 21.18 | 21.10 | 21.33 | 22.65 | 24.55 | 24.02 | 23.83 | 23.57 | 23.18 |
| 6 | 24.90 | 25.54 | 26.11 | 26.61 | 26.78 | 26.85 | 26.77 | 26.99 | 28.62 | 30.99 | 30.22 | 29.94 | 29.53 | 28.91 |
| 7 | 29.17 | 30.15 | 31.16 | 32.02 | 32.53 | 32.75 | 32.75 | 32.99 | 34.98 | 37.87 | 36.88 | 36.50 | 35.94 | 34.99 |
| 8 | 32.70 | 34.24 | 35.66 | 36.93 | 37.78 | 38.31 | 38.59 | 39.01 | 41.44 | 45.01 | 43.87 | 43.36 | 42.59 | 41.33 |
| 9 | 36.02 | 38.10 | 39.99 | 41.66 | 42.81 | 43.53 | 43.94 | 44.43 | 47.20 | 51.27 | 50.10 | 49.58 | 48.80 | 47.44 |
| 10 | 39.08 | 41.73 | 44.15 | 46.27 | 47.75 | 48.72 | 49.29 | 49.90 | 53.02 | 57.59 | 56.25 | 55.64 | 54.71 | 53.05 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 64.964 | 56.251 |
| SC2 | 0 | 8 | 44.741 | 39.012 |
| SC3 | -18 | 7 | 36.817 | 32.263 |
| SC4 | -25 | 6 | 29.849 | 26.113 |
| SC5 | -34 | 6 | 28.284 | 25.076 |
| A | 3615 mm |
|---|---|
| B | 900 mm |
| C | 1190 mm |
| F | 860 mm |
| E1 | 818 mm |
| E2 | 800 mm |
| E | 3235 mm |
| D IN | 1 x Ø35 |
| D OUT | 1 x Ø54 |
| Length | 3615 mm |
|---|---|
| Width | 900 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.