EA-563FG10-C19 C
95.13 kW
Defrost: None
Product code: EA-563FE7-C08 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 74,195 m³/h |
|---|---|
| Air throw | 44 m |
| External surface | 422.5 m² |
| Inner volume | 127.0 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 625 kg |
| Quantity | 5 |
|---|---|
| Diameter | 630 mm |
| Speed | 1,340 rpm |
| Power | 9,500 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 75.0 dB(A) |
|---|---|
| Sound power | 99.0 dB(A) |
| Energy class | E |
| Inlet | Ø54 |
|---|---|
| Outlet | Ø66,7 |
| EA-563FE7-C08 C | None |
|---|---|
| EA-563FE7-C08 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 35.69 | 35.55 | 35.54 | 35.61 | 35.49 | 35.26 | 34.96 | 35.33 | 37.39 | 40.40 | 39.43 | 39.07 | 38.57 | 37.82 |
| 5 | 47.11 | 47.59 | 48.05 | 48.47 | 48.43 | 48.20 | 47.77 | 48.21 | 51.12 | 55.24 | 53.81 | 53.31 | 52.61 | 51.46 |
| 6 | 57.95 | 59.45 | 60.77 | 61.85 | 62.10 | 62.08 | 61.69 | 62.18 | 65.87 | 71.17 | 69.20 | 68.48 | 67.45 | 65.88 |
| 7 | 68.07 | 70.44 | 72.85 | 74.90 | 76.04 | 76.46 | 76.30 | 76.89 | 81.51 | 88.13 | 85.64 | 84.68 | 83.28 | 81.05 |
| 8 | 76.30 | 80.03 | 83.45 | 86.47 | 88.47 | 89.68 | 90.24 | 91.33 | 97.02 | 105.34 | 102.83 | 101.69 | 99.98 | 97.20 |
| 9 | 84.10 | 89.12 | 93.68 | 97.68 | 100.43 | 102.15 | 103.05 | 104.33 | 110.85 | 120.40 | 117.73 | 116.63 | 114.98 | 112.23 |
| 10 | 91.27 | 97.66 | 103.49 | 108.61 | 112.23 | 114.57 | 115.88 | 117.42 | 124.78 | 135.59 | 132.66 | 131.41 | 129.52 | 126.32 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 31.60 | 31.34 | 31.26 | 31.31 | 31.23 | 31.07 | 30.85 | 31.43 | 33.29 | 36.04 | 35.26 | 34.97 | 34.57 | 33.97 |
| 5 | 41.63 | 41.72 | 41.84 | 42.11 | 42.10 | 41.90 | 41.55 | 42.05 | 44.65 | 48.33 | 47.17 | 46.77 | 46.21 | 45.40 |
| 6 | 51.34 | 52.12 | 52.87 | 53.55 | 53.76 | 53.62 | 53.18 | 53.63 | 56.86 | 61.47 | 59.79 | 59.18 | 58.32 | 57.01 |
| 7 | 60.59 | 62.29 | 63.82 | 64.88 | 65.54 | 65.66 | 65.36 | 65.79 | 69.72 | 75.38 | 73.18 | 72.35 | 71.15 | 69.24 |
| 8 | 69.24 | 71.58 | 74.02 | 76.23 | 77.48 | 77.99 | 77.90 | 78.41 | 83.10 | 89.92 | 87.32 | 86.29 | 84.78 | 82.30 |
| 9 | 76.33 | 79.94 | 83.27 | 86.23 | 88.18 | 89.36 | 89.88 | 90.83 | 96.44 | 104.68 | 101.89 | 100.69 | 98.90 | 95.93 |
| 10 | 83.16 | 87.90 | 92.22 | 96.02 | 98.62 | 100.18 | 101.00 | 102.13 | 108.45 | 117.70 | 115.01 | 113.85 | 112.11 | 109.16 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 132.659 | 115.014 |
| SC2 | 0 | 8 | 91.328 | 78.414 |
| SC3 | -18 | 7 | 75.447 | 65.215 |
| SC4 | -25 | 6 | 60.766 | 52.868 |
| SC5 | -34 | 6 | 58.356 | 51.578 |
| A | 5415 mm |
|---|---|
| B | 1000 mm |
| C | 1190 mm |
| F | 960 mm |
| G | 1035 mm |
| E1 | 1018 mm |
| E2 | 1000 mm |
| E | 5035 mm |
| D IN | 1 x Ø54 |
| D OUT | 1 x Ø66,7 |
| Length | 5415 mm |
|---|---|
| Width | 1000 mm |
| Height | 1190 mm |
Our engineers answer with a selection for your conditions.