Skip to Content

Unit cooler EA-HL-250AC10-A10 C

Unit cooler EA-HL-250AC10-A10 C
Illustrative photo

Producer: Karyer · Line: EA-HL (High Type)

Product code: EA-HL-250AC10-A10 C

Cooling capacity i
19.16 kW
Air flow
16,254 m³/h
Fin spacing
10.0 mm
Air throw
24 m
Fans
2 × ⌀500 mm

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Model nomenclature

How to read the code of this model.

  • A
    Model code (series): EA-HL — EA-HL - high-type EA unit cooler (Ø500 fans)
  • B
    Number of fans: 2 — Number of fans (one digit).
  • C
    Fan diameter: 50 — Ø500 mm
  • D
    Dimensional data - coil size letter: A — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows: C — 4 tube rows
  • F
    Fin spacing: 10 — Fin spacing about 10 mm
  • G
    Generation code: A — Generation A
  • H
    Fan data: 10 — Ø500: 400V/3Ph/50Hz, 4-pole

Data

Evaporator
Air flow 16,254 m³/h
Air throw 24 m
External surface 46.5 m²
Inner volume 21.6 dm³
Fin spacing 10.0 mm
Fin materialAluminium
Net weight 141 kg
Fans
Quantity 2
Diameter 500 mm
Speed 1,360 rpm
Power 1,380 W
Supply 400V/3Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 62.0 dB(A)
Sound power 84.0 dB(A)
Energy class D
Connections
Inlet Ø19
Outlet Ø35
Defrost
EA-HL-250AC10-A10 C None
EA-HL-250AC10-A10 C ED Electric

Performance

No glide: dew, mid and bubble point give the same rating.

TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.

R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)

High speed (Δ)
18.421 kW
Low speed (Y)
16.344 kW

Capacity matrix [kW]

R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.

High speed (Δ)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 6.89 6.86 6.86 6.87 6.84 6.78 6.71 6.70 7.07 7.61 7.39 7.30 7.18 7.00
5 9.12 9.25 9.38 9.50 9.54 9.52 9.46 9.46 10.01 10.80 10.49 10.38 10.21 9.96
6 11.33 11.64 11.94 12.18 12.34 12.42 12.42 12.46 13.20 14.27 13.89 13.74 13.53 13.19
7 13.33 13.87 14.38 14.86 15.19 15.38 15.48 15.57 16.52 17.88 17.46 17.30 17.05 16.65
8 15.05 15.80 16.51 17.17 17.58 17.93 18.18 18.42 19.60 21.33 20.98 20.82 20.60 20.24
9 16.63 17.64 18.47 19.33 19.97 20.44 20.79 21.10 22.46 24.46 24.09 23.93 23.68 23.27
10 18.09 19.25 20.42 21.50 22.32 22.94 23.39 23.78 25.33 27.61 27.23 27.06 26.79 26.33

Low speed (Y)

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 6.20 6.15 6.13 6.14 6.11 6.06 6.01 6.03 6.37 6.87 6.68 6.62 6.52 6.37
5 8.22 8.27 8.35 8.43 8.45 8.43 8.37 8.40 8.89 9.60 9.34 9.24 9.11 8.90
6 10.17 10.38 10.59 10.79 10.90 10.93 10.91 10.96 11.61 12.56 12.22 12.09 11.90 11.62
7 12.09 12.47 12.84 13.18 13.40 13.50 13.55 13.63 14.46 15.66 15.27 15.12 14.89 14.52
8 13.80 14.37 14.92 15.44 15.81 16.08 16.23 16.34 17.34 18.83 18.41 18.24 17.99 17.56
9 15.31 16.08 16.81 17.49 17.92 18.29 18.54 18.80 20.00 21.77 21.41 21.25 21.01 20.61
10 16.71 17.71 18.55 19.41 20.05 20.52 20.86 21.18 22.54 24.55 24.17 24.00 23.74 23.28

Standard ratings (EN 328 / Eurovent)

Standard condition Air inlet [°C] TD [K] High speed (Δ) [kW]Low speed (Y) [kW]
SC1 10 10 27.22824.168
SC2 0 8 18.42116.344
SC3 -18 7 15.01013.283
SC4 -25 6 11.93710.587
SC5 -34 6 11.40910.225

Dimensions

Dimension drawing of EA-HL-250AC10-A10 C
Dimension drawing
Dimensions as drawn
A 2387 mm
B 590 mm
C 875 mm
F 510 mm
E1 1018 mm
E 2035 mm
D IN 1 x Ø19
D OUT 1 x Ø35
Overall [mm]
Length 2387 mm
Width 590 mm
Height 875 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.