EB (General)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.64–32.06 kW
Fans
⌀200, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450 mm
Max. working pressure
25 bar
EB (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EB = EB - economical unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • H
    Fan data 01 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole05 = Ø200: 230V/1Ph/50Hz, 4-pole; Ø250: 230V/1Ph/50Hz, 4-pole; Ø300: 230V/1Ph/50Hz, 4-pole07 = Ø450: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EB-120AB7-B05 C 0.64 kW 7.0 1 × ⌀200 3 446 None, Electric
Variants (2)
EB-125AA7-B05 C 0.75 kW 7.0 1 × ⌀250 5 906 None, Electric
Variants (2)
EB-120AC7-B05 C 0.79 kW 7.0 1 × ⌀200 3 432 None, Electric
Variants (2)
EB-125AA6-B05 C 0.82 kW 6.0 1 × ⌀250 5 901 None, Electric
Variants (2)
EB-120AB4-B05 C 0.84 kW 4.2 1 × ⌀200 3 434 None, Electric
Variants (2)
EB-125BA7-B05 C 0.85 kW 7.0 1 × ⌀250 5 922 None, Electric
Variants (2)
EB-125AB7-B05 C 0.93 kW 7.0 1 × ⌀250 5 864 None, Electric
Variants (2)
EB-125BA6-B05 C 0.93 kW 6.0 1 × ⌀250 5 918 None, Electric
Variants (2)
EB-120AC4-B05 C 0.99 kW 4.2 1 × ⌀200 3 417 None, Electric
Variants (2)
EB-125AA4-B05 C 1.04 kW 4.2 1 × ⌀250 5 882 None, Electric
Variants (2)
EB-120AE7-B05 C 1.04 kW 7.0 1 × ⌀200 3 407 None, Electric
Variants (2)
EB-125BA4-B05 C 1.09 kW 4.2 1 × ⌀250 5 908 None, Electric
Variants (2)
EB-125AB6-B05 C 1.10 kW 6.0 1 × ⌀250 5 853 None, Electric
Variants (2)
EB-125BB7-B05 C 1.13 kW 7.0 1 × ⌀250 5 897 None, Electric
Variants (2)
EB-125BB6-B05 C 1.26 kW 6.0 1 × ⌀250 5 889 None, Electric
Variants (2)
EB-125AC7-B05 C 1.29 kW 7.0 1 × ⌀250 5 821 None, Electric
Variants (2)
EB-125AB4-B05 C 1.31 kW 4.2 1 × ⌀250 5 827 None, Electric
Variants (2)
EB-220AB7-B05 C 1.32 kW 7.0 2 × ⌀200 4 892 None, Electric
Variants (2)
EB-130AB7-B05 C 1.35 kW 7.0 1 × ⌀300 6 1,263 None, Electric
Variants (2)
EB-125AC6-B05 C 1.39 kW 6.0 1 × ⌀250 5 810 None, Electric
Variants (2)
EB-125BB4-B05 C 1.41 kW 4.2 1 × ⌀250 5 867 None, Electric
Variants (2)
EB-125BC7-B05 C 1.45 kW 7.0 1 × ⌀250 5 862 None, Electric
Variants (2)
EB-130AB7-B01 C 1.46 kW 7.0 1 × ⌀300 7 1,410 None, Electric
Variants (2)
EB-130AB6-B05 C 1.47 kW 6.0 1 × ⌀300 6 1,241 None, Electric
Variants (2)
EB-130BB7-B05 C 1.54 kW 7.0 1 × ⌀300 7 1,334 None, Electric
Variants (2)
EB-225AA7-B05 C 1.54 kW 7.0 2 × ⌀250 6 1,812 None, Electric
Variants (2)
EB-125BC6-B05 C 1.55 kW 6.0 1 × ⌀250 5 852 None, Electric
Variants (2)
EB-220AC7-B05 C 1.58 kW 7.0 2 × ⌀200 3 863 None, Electric
Variants (2)
EB-130AB6-B01 C 1.59 kW 6.0 1 × ⌀300 7 1,390 None, Electric
Variants (2)
EB-125AC4-B05 C 1.59 kW 4.2 1 × ⌀250 5 775 None, Electric
Variants (2)
EB-130BB7-B01 C 1.64 kW 7.0 1 × ⌀300 7 1,481 None, Electric
Variants (2)
EB-220AB4-B05 C 1.66 kW 4.2 2 × ⌀200 3 867 None, Electric
Variants (2)
EB-130BB6-B05 C 1.67 kW 6.0 1 × ⌀300 7 1,318 None, Electric
Variants (2)
EB-225AA6-B05 C 1.69 kW 6.0 2 × ⌀250 6 1,803 None, Electric
Variants (2)
EB-225BA7-B05 C 1.70 kW 7.0 2 × ⌀250 6 1,843 None, Electric
Variants (2)
EB-130AC7-B05 C 1.73 kW 7.0 1 × ⌀300 6 1,168 None, Electric
Variants (2)
EB-125BC4-B05 C 1.74 kW 4.2 1 × ⌀250 5 827 None, Electric
Variants (2)
EB-130AB4-B05 C 1.75 kW 4.2 1 × ⌀300 6 1,183 None, Electric
Variants (2)
EB-130BB6-B01 C 1.78 kW 6.0 1 × ⌀300 7 1,464 None, Electric
Variants (2)
EB-130AC7-B01 C 1.82 kW 7.0 1 × ⌀300 7 1,319 None, Electric
Variants (2)
EB-130AC6-B05 C 1.85 kW 6.0 1 × ⌀300 6 1,144 None, Electric
Variants (2)
EB-130AB4-B01 C 1.85 kW 4.2 1 × ⌀300 7 1,333 None, Electric
Variants (2)
EB-225BA6-B05 C 1.87 kW 6.0 2 × ⌀250 6 1,836 None, Electric
Variants (2)
EB-130BC7-B05 C 1.91 kW 7.0 1 × ⌀300 6 1,262 None, Electric
Variants (2)
EB-130AC6-B01 C 1.93 kW 6.0 1 × ⌀300 7 1,296 None, Electric
Variants (2)
EB-220AC4-B05 C 2.00 kW 4.2 2 × ⌀200 3 834 None, Electric
Variants (2)
EB-130AC4-B05 C 2.01 kW 4.2 1 × ⌀300 6 1,079 None, Electric
Variants (2)
EB-130BB4-B05 C 2.05 kW 4.2 1 × ⌀300 6 1,274 None, Electric
Variants (2)
EB-130BC7-B01 C 2.05 kW 7.0 1 × ⌀300 7 1,409 None, Electric
Variants (2)
EB-130BC6-B05 C 2.06 kW 6.0 1 × ⌀300 6 1,240 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.