Skip to Content

EB (General)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.64–32.06 kW
Fans
⌀200, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450 mm
Max. working pressure
25 bar
EB (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EB = EB - economical unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • H
    Fan data 01 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole05 = Ø200: 230V/1Ph/50Hz, 4-pole; Ø250: 230V/1Ph/50Hz, 4-pole; Ø300: 230V/1Ph/50Hz, 4-pole07 = Ø450: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EB-225AA4-B05 C 2.10 kW 4.2 2 × ⌀250 6 1,763 None, Electric
Variants (2)
EB-220AE7-B05 C 2.12 kW 7.0 2 × ⌀200 3 814 None, Electric
Variants (2)
EB-130AE7-B05 C 2.13 kW 7.0 1 × ⌀300 5 1,018 None, Electric
Variants (2)
EB-130AC4-B01 C 2.15 kW 4.2 1 × ⌀300 6 1,240 None, Electric
Variants (2)
EB-225AB7-B05 C 2.16 kW 7.0 2 × ⌀250 6 1,723 None, Electric
Variants (2)
EB-130BB4-B01 C 2.17 kW 4.2 1 × ⌀300 7 1,419 None, Electric
Variants (2)
EB-320AB7-C05 C 2.18 kW 7.0 3 × ⌀200 4 1,351 None, Electric
Variants (2)
EB-130BC6-B01 C 2.21 kW 6.0 1 × ⌀300 7 1,389 None, Electric
Variants (2)
EB-325AA7-B05 C 2.24 kW 7.0 3 × ⌀250 6 2,718 None, Electric
Variants (2)
EB-130AE6-B05 C 2.24 kW 6.0 1 × ⌀300 5 991 None, Electric
Variants (2)
EB-225BA4-B05 C 2.32 kW 4.2 2 × ⌀250 6 1,816 None, Electric
Variants (2)
EB-130BC4-B05 C 2.34 kW 4.2 1 × ⌀300 6 1,182 None, Electric
Variants (2)
EB-225AB6-B05 C 2.34 kW 6.0 2 × ⌀250 6 1,704 None, Electric
Variants (2)
EB-130AE7-B01 C 2.38 kW 7.0 1 × ⌀300 6 1,187 None, Electric
Variants (2)
EB-225BB7-B05 C 2.40 kW 7.0 2 × ⌀250 6 1,793 None, Electric
Variants (2)
EB-130AE4-B05 C 2.44 kW 4.2 1 × ⌀300 5 929 None, Electric
Variants (2)
EB-325BA7-B05 C 2.47 kW 7.0 3 × ⌀250 6 2,765 None, Electric
Variants (2)
EB-130BE7-B05 C 2.49 kW 7.0 1 × ⌀300 6 1,129 None, Electric
Variants (2)
EB-325AA6-B05 C 2.49 kW 6.0 3 × ⌀250 6 2,704 None, Electric
Variants (2)
EB-130AE6-B01 C 2.51 kW 6.0 1 × ⌀300 6 1,161 None, Electric
Variants (2)
EB-130BC4-B01 C 2.53 kW 4.2 1 × ⌀300 7 1,332 None, Electric
Variants (2)
EB-130BE6-B05 C 2.63 kW 6.0 1 × ⌀300 6 1,102 None, Electric
Variants (2)
EB-225AC7-B05 C 2.63 kW 7.0 2 × ⌀250 5 1,642 None, Electric
Variants (2)
EB-320AC7-C05 C 2.63 kW 7.0 3 × ⌀200 4 1,307 None, Electric
Variants (2)
EB-320AB4-C05 C 2.63 kW 4.2 3 × ⌀200 4 1,313 None, Electric
Variants (2)
EB-225BB6-B05 C 2.71 kW 6.0 2 × ⌀250 6 1,777 None, Electric
Variants (2)
EB-420AB7-B05 C 2.72 kW 7.0 4 × ⌀200 4 1,783 None, Electric
Variants (2)
EB-325BA6-B05 C 2.73 kW 6.0 3 × ⌀250 6 2,755 None, Electric
Variants (2)
EB-130BE7-B01 C 2.73 kW 7.0 1 × ⌀300 7 1,281 None, Electric
Variants (2)
EB-130BE4-B05 C 2.74 kW 4.2 1 × ⌀300 5 1,034 None, Electric
Variants (2)
EB-230AB7-B05 C 2.75 kW 7.0 2 × ⌀300 7 2,523 None, Electric
Variants (2)
EB-130AE4-B01 C 2.76 kW 4.2 1 × ⌀300 6 1,096 None, Electric
Variants (2)
EB-225AB4-B05 C 2.76 kW 4.2 2 × ⌀250 5 1,653 None, Electric
Variants (2)
EB-225AC6-B05 C 2.83 kW 6.0 2 × ⌀250 5 1,620 None, Electric
Variants (2)
EB-130BE6-B01 C 2.89 kW 6.0 1 × ⌀300 6 1,259 None, Electric
Variants (2)
EB-230AB7-B01 C 2.93 kW 7.0 2 × ⌀300 8 2,817 None, Electric
Variants (2)
EB-230AB6-B05 C 2.93 kW 6.0 2 × ⌀300 7 2,480 None, Electric
Variants (2)
EB-225BC7-B05 C 3.02 kW 7.0 2 × ⌀250 6 1,723 None, Electric
Variants (2)
EB-230BB7-B05 C 3.03 kW 7.0 2 × ⌀300 7 2,668 None, Electric
Variants (2)
EB-325AA4-B05 C 3.06 kW 4.2 3 × ⌀250 6 2,646 None, Electric
Variants (2)
EB-130BE4-B01 C 3.06 kW 4.2 1 × ⌀300 6 1,201 None, Electric
Variants (2)
EB-225BB4-B05 C 3.09 kW 4.2 2 × ⌀250 6 1,733 None, Electric
Variants (2)
EB-425AA7-B05 C 3.11 kW 7.0 4 × ⌀250 6 3,622 None, Electric
Variants (2)
EB-325AB7-B05 C 3.12 kW 7.0 3 × ⌀250 6 2,586 None, Electric
Variants (2)
EB-230AB6-B01 C 3.12 kW 6.0 2 × ⌀300 8 2,777 None, Electric
Variants (2)
EB-320AC4-C05 C 3.16 kW 4.2 3 × ⌀200 3 1,265 None, Electric
Variants (2)
EB-225AC4-B05 C 3.19 kW 4.2 2 × ⌀250 5 1,551 None, Electric
Variants (2)
EB-230BB7-B01 C 3.22 kW 7.0 2 × ⌀300 8 2,963 None, Electric
Variants (2)
EB-225BC6-B05 C 3.24 kW 6.0 2 × ⌀250 6 1,704 None, Electric
Variants (2)
EB-320AE7-C05 C 3.27 kW 7.0 3 × ⌀200 3 1,237 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.