Skip to Content

EC-A (Celling Type)

Application
Ceiling mounted (flat), Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.32–1.54 kW
Fans
⌀200 mm
Max. working pressure
25 bar
EC-A (Celling Type)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EC-A = EC-A - commercial ceiling-type evaporator, aluminium casing
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). C = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=3.5/7.0, 6=5.0/10.0 (staggered fin spacing). The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. C = Generation C
  • H
    Fan data 25 = Ø200: 230V/1Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EC-A-120BC6-C25 C 0.32 kW 5.7 1 × ⌀200 4 257 None, Electric
Variants (2)
EC-A-120EC4-C25 C 0.33 kW 4.0 1 × ⌀200 3 241 None
Variants (1)
EC-A-120OC6-C25 C 0.37 kW 5.7 1 × ⌀200 3 225 None, Electric
Variants (2)
EC-A-120FC4-C25 C 0.41 kW 4.0 1 × ⌀200 3 241 None
Variants (1)
EC-A-120OC4-C25 C 0.41 kW 4.0 1 × ⌀200 3 210 None
Variants (1)
EC-A-120NE4-C25 C 0.42 kW 3.8 1 × ⌀200 3 178 None
Variants (1)
EC-A-120BE6-C25 C 0.46 kW 5.5 1 × ⌀200 3 220 None, Electric
Variants (2)
EC-A-120AE4-C25 C 0.46 kW 3.8 1 × ⌀200 3 205 None
Variants (1)
EC-A-120OE6-C25 C 0.47 kW 5.5 1 × ⌀200 3 191 None, Electric
Variants (2)
EC-A-120OE4-C25 C 0.49 kW 3.8 1 × ⌀200 3 177 None
Variants (1)
EC-A-120BE4-C25 C 0.50 kW 3.8 1 × ⌀200 3 205 None
Variants (1)
EC-A-220KC4-C25 C 0.64 kW 4.0 2 × ⌀200 4 374 None
Variants (1)
EC-A-220OC6-C25 C 0.65 kW 5.7 2 × ⌀200 4 399 None, Electric
Variants (2)
EC-A-220JE6-C25 C 0.71 kW 5.5 2 × ⌀200 4 338 None, Electric
Variants (2)
EC-A-220OC4-C25 C 0.73 kW 4.0 2 × ⌀200 4 373 None
Variants (1)
EC-A-220KE6-C25 C 0.80 kW 5.5 2 × ⌀200 4 337 None, Electric
Variants (2)
EC-A-220KE4-C25 C 0.86 kW 3.8 2 × ⌀200 3 312 None
Variants (1)
EC-A-320JC6-C25 C 1.02 kW 5.7 3 × ⌀200 5 716 None, Electric
Variants (2)
EC-A-320JC4-C25 C 1.21 kW 4.0 3 × ⌀200 5 673 None
Variants (1)
EC-A-320JE6-C25 C 1.25 kW 5.5 3 × ⌀200 5 612 None, Electric
Variants (2)
EC-A-320KC4-C25 C 1.39 kW 4.0 3 × ⌀200 5 672 None
Variants (1)
EC-A-320KE6-C25 C 1.45 kW 5.5 3 × ⌀200 5 612 None, Electric
Variants (2)
EC-A-320KE4-C25 C 1.54 kW 3.8 3 × ⌀200 4 571 None
Variants (1)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.