ED-DP-435AE4-B22 C
16.36 kW
Defrost: None
Product code: ED-DP-440AC7-B22 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 9,994 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 60.6 m² |
| Inner volume | 19.6 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 162 kg |
| Quantity | 4 |
|---|---|
| Diameter | 400 mm |
| Speed | 870 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 6 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.3 dB(A) |
| Energy class | B |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø35 |
| ED-DP-440AC7-B22 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.22 | 6.16 | 6.14 | 6.14 | 6.12 | 6.08 | 6.02 | 6.11 | 6.50 | 7.03 | 6.86 | 6.80 | 6.72 | 6.60 |
| 5 | 8.24 | 8.26 | 8.31 | 8.37 | 8.37 | 8.33 | 8.26 | 8.34 | 8.85 | 9.57 | 9.32 | 9.23 | 9.12 | 8.95 |
| 6 | 10.22 | 10.38 | 10.54 | 10.70 | 10.76 | 10.75 | 10.69 | 10.76 | 11.41 | 12.33 | 11.98 | 11.85 | 11.66 | 11.38 |
| 7 | 12.18 | 12.49 | 12.80 | 13.08 | 13.21 | 13.27 | 13.24 | 13.32 | 14.12 | 15.27 | 14.83 | 14.66 | 14.40 | 13.98 |
| 8 | 13.92 | 14.42 | 14.90 | 15.35 | 15.65 | 15.83 | 15.85 | 15.96 | 16.92 | 18.30 | 17.80 | 17.59 | 17.27 | 16.73 |
| 9 | 15.48 | 16.16 | 16.81 | 17.41 | 17.76 | 18.02 | 18.17 | 18.39 | 19.53 | 21.21 | 20.75 | 20.54 | 20.21 | 19.58 |
| 10 | 16.92 | 17.83 | 18.59 | 19.34 | 19.87 | 20.23 | 20.44 | 20.71 | 22.00 | 23.90 | 23.39 | 23.15 | 22.79 | 22.16 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 23.391 |
| SC2 | 0 | 8 | 15.958 |
| SC3 | -18 | 7 | 13.153 |
| SC4 | -25 | 6 | 10.539 |
| SC5 | -34 | 6 | 10.264 |
| A | 2748 mm |
|---|---|
| B | 1050 mm |
| C | 435 mm |
| F | 1090 mm |
| G | 570 mm |
| E1 | 2435 mm |
| E2 | 618 mm |
| E3 | 600 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø35 |
| Length | 2748 mm |
|---|---|
| Width | 1050 mm |
| Height | 570 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.