ED-DR-445BA4-A27 C
13.33 kW
Defrost: None
Product code: ED-DR-345AA5-A27 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 19,432 m³/h |
|---|---|
| Air throw | 19 m |
| External surface | 64.1 m² |
| Inner volume | 11.4 dm³ |
| Fin spacing | 5.0 mm |
| Fin material | Aluminium |
| Net weight | 150 kg |
| Quantity | 3 |
|---|---|
| Diameter | 450 mm |
| Speed | 1,360 rpm |
| Power | 1,440 W |
| Supply | 400V/3Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 58.0 dB(A) |
|---|---|
| Sound power | 80.8 dB(A) |
| Energy class | E |
| Inlet | Ø19 |
|---|---|
| Outlet | Ø28 |
| ED-DR-345AA5-A27 C | None |
|---|
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.58 | 5.51 | 5.46 | 5.44 | 5.40 | 5.35 | 5.30 | 5.29 | 5.60 | 6.04 | 5.90 | 5.84 | 5.77 | 5.66 |
| 5 | 7.49 | 7.52 | 7.55 | 7.57 | 7.53 | 7.47 | 7.39 | 7.36 | 7.78 | 8.39 | 8.15 | 8.06 | 7.93 | 7.74 |
| 6 | 9.29 | 9.49 | 9.68 | 9.81 | 9.85 | 9.82 | 9.75 | 9.72 | 10.28 | 11.07 | 10.74 | 10.61 | 10.44 | 10.17 |
| 7 | 10.79 | 11.13 | 11.45 | 11.74 | 11.92 | 12.03 | 12.08 | 12.14 | 12.89 | 13.96 | 13.62 | 13.46 | 13.23 | 12.88 |
| 8 | 12.19 | 12.72 | 13.20 | 13.62 | 13.89 | 14.05 | 14.14 | 14.23 | 15.10 | 16.37 | 16.02 | 15.88 | 15.67 | 15.34 |
| 9 | 13.49 | 14.23 | 14.89 | 15.46 | 15.85 | 16.10 | 16.24 | 16.36 | 17.37 | 18.84 | 18.44 | 18.28 | 18.04 | 17.65 |
| 10 | 14.69 | 15.65 | 16.52 | 17.27 | 17.80 | 18.14 | 18.35 | 18.52 | 19.67 | 21.35 | 20.91 | 20.73 | 20.46 | 20.01 |
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.10 | 5.02 | 4.98 | 4.97 | 4.94 | 4.91 | 4.87 | 4.88 | 5.17 | 5.59 | 5.46 | 5.41 | 5.35 | 5.25 |
| 5 | 6.84 | 6.83 | 6.83 | 6.84 | 6.81 | 6.75 | 6.69 | 6.69 | 7.08 | 7.64 | 7.44 | 7.37 | 7.26 | 7.10 |
| 6 | 8.56 | 8.67 | 8.74 | 8.83 | 8.84 | 8.81 | 8.74 | 8.73 | 9.23 | 9.95 | 9.66 | 9.56 | 9.41 | 9.19 |
| 7 | 10.02 | 10.28 | 10.52 | 10.76 | 10.90 | 10.98 | 10.95 | 10.95 | 11.59 | 12.50 | 12.14 | 12.00 | 11.80 | 11.49 |
| 8 | 11.36 | 11.76 | 12.13 | 12.47 | 12.68 | 12.81 | 12.87 | 12.96 | 13.75 | 14.91 | 14.58 | 14.45 | 14.27 | 13.97 |
| 9 | 12.61 | 13.18 | 13.71 | 14.17 | 14.47 | 14.66 | 14.76 | 14.87 | 15.78 | 17.12 | 16.74 | 16.60 | 16.38 | 16.02 |
| 10 | 13.76 | 14.54 | 15.23 | 15.84 | 16.25 | 16.52 | 16.67 | 16.81 | 17.85 | 19.37 | 18.95 | 18.78 | 18.53 | 18.12 |
| Standard condition | Air inlet [°C] | TD [K] | High speed (Δ) [kW] | Low speed (Y) [kW] |
|---|---|---|---|---|
| SC1 | 10 | 10 | 20.907 | 18.951 |
| SC2 | 0 | 8 | 14.231 | 12.957 |
| SC3 | -18 | 7 | 11.826 | 10.821 |
| SC4 | -25 | 6 | 9.676 | 8.740 |
| SC5 | -34 | 6 | 9.346 | 8.593 |
| A | 3708 mm |
|---|---|
| B | 1215 mm |
| C | 290 mm |
| F | 1165 mm |
| G | 360 mm |
| E1 | 1138 mm |
| E2 | 1120 mm |
| E | 3395 mm |
| D IN | 1 x Ø19 |
| D OUT | 1 x Ø28 |
| Length | 3708 mm |
|---|---|
| Width | 1215 mm |
| Height | 360 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.