ED-240AC4-C21 C
12.40 kW
Defrost: Electric
Product code: ED-630AC7-C25 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 7,539 m³/h |
|---|---|
| Air throw | 10 m |
| External surface | 47.2 m² |
| Inner volume | 14.5 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 121 kg |
| Quantity | 6 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 720 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.0 dB(A) |
| Energy class | D |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| ED-630AC7-C25 C | None |
|---|---|
| ED-630AC7-C25 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.59 | 4.63 | 4.69 | 4.74 | 4.75 | 4.73 | 4.70 | 4.77 | 5.07 | 5.49 | 5.37 | 5.32 | 5.25 | 5.14 |
| 5 | 5.95 | 6.11 | 6.26 | 6.40 | 6.46 | 6.48 | 6.45 | 6.53 | 6.94 | 7.52 | 7.32 | 7.25 | 7.16 | 7.01 |
| 6 | 7.28 | 7.58 | 7.86 | 8.10 | 8.24 | 8.30 | 8.30 | 8.40 | 8.92 | 9.66 | 9.41 | 9.31 | 9.16 | 8.93 |
| 7 | 8.44 | 8.88 | 9.28 | 9.65 | 9.90 | 10.03 | 10.13 | 10.28 | 10.94 | 11.88 | 11.58 | 11.46 | 11.28 | 10.98 |
| 8 | 9.45 | 10.05 | 10.53 | 11.03 | 11.38 | 11.62 | 11.76 | 11.95 | 12.71 | 13.83 | 13.55 | 13.43 | 13.25 | 12.93 |
| 9 | 10.38 | 11.08 | 11.78 | 12.41 | 12.87 | 13.19 | 13.39 | 13.62 | 14.49 | 15.77 | 15.48 | 15.34 | 15.12 | 14.75 |
| 10 | 11.22 | 12.09 | 12.96 | 13.74 | 14.32 | 14.74 | 15.01 | 15.30 | 16.29 | 17.73 | 17.41 | 17.26 | 17.02 | 16.59 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 17.414 |
| SC2 | 0 | 8 | 11.949 |
| SC3 | -18 | 7 | 9.763 |
| SC4 | -25 | 6 | 7.855 |
| SC5 | -34 | 6 | 7.352 |
| A | 3348 mm |
|---|---|
| B | 1030 mm |
| C | 245 mm |
| F | 985 mm |
| G | 305 mm |
| E1 | 3035 mm |
| E2 | 518 mm |
| E3 | 500 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 3348 mm |
|---|---|
| Width | 1030 mm |
| Height | 305 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.