Skip to Content

Unit cooler EM-235AB4-C21 C

Unit cooler EM-235AB4-C21 C
Illustrative photo

Producer: Karyer · Line: EM (Low Speed Ceiling)

Product code: EM-235AB4-C21 C

Cooling capacity i
13.55 kW
Air flow
6,416 m³/h
Fin spacing
4.2 mm
Air throw
5 m
Fans
2 × ⌀350 mm

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Model nomenclature

How to read the code of this model.

  • A
    Model code (series): EM — EM - low-speed ceiling-type unit cooler
  • B
    Number of fans: 2 — Number of fans (one digit).
  • C
    Fan diameter: 35 — Ø350 mm
  • D
    Dimensional data - coil size letter: A — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows: B — 3 tube rows
  • F
    Fin spacing: 4 — Fin spacing about 4 mm
  • G
    Generation code: C — Generation C
  • H
    Fan data: 21 — Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole

Data

Evaporator
Air flow 6,416 m³/h
Air throw 5 m
External surface 79.0 m²
Inner volume 12.4 dm³
Fin spacing 4.2 mm
Fin materialAluminium
Net weight 106 kg
Fans
Quantity 2
Diameter 350 mm
Speed 1,340 rpm
Power 330 W
Supply 230V/1Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 54.0 dB(A)
Sound power 76.8 dB(A)
Energy class B
Connections
Inlet Ø15,9
Outlet Ø28
Defrost
EM-235AB4-C21 C None

Performance

No glide: dew, mid and bubble point give the same rating.

TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.

R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)

Single phase
13.061 kW

Capacity matrix [kW]

R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.

≈ 1.23 estimate — vendor data irregular here

Single phase

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 5.13 5.27 5.42 5.56 5.66 5.73 5.77 5.82 6.19 6.72 6.61 6.56 6.50 6.40
5 6.44 6.72 6.98 7.23 7.40 7.53 7.62 7.70 8.18 8.89 8.74 8.69 8.60 8.45
6 7.63 8.04 8.43 8.79 9.07 9.28 9.43 9.57 10.19 11.10 10.95 10.89 10.80 10.62
7 8.69 9.25 9.78 10.27 10.64 10.92 11.14 11.31 12.05 13.14 12.97 12.90 12.79 12.60
8 9.76 10.47 11.14 11.76 12.23 12.59 12.84 13.06 13.92 15.19 15.01 14.90 14.78 14.56
9 10.65 11.55 12.39 13.16 13.76 14.21 14.50 14.78 15.76 17.19 17.01 16.93 16.80 16.56
10 ≈ 11.46 12.54 13.57 14.51 15.14 15.72 16.16 16.51 17.62 19.25 19.07 18.98 18.84 18.58

Standard ratings (EN 328 / Eurovent)

Standard condition Air inlet [°C] TD [K] Single phase [kW]
SC1 10 10 19.070
SC2 0 8 13.061
SC3 -18 7 10.431
SC4 -25 6 8.430
SC5 -34 6 7.728

Dimensions

Dimension drawing of EM-235AB4-C21 C
Dimension drawing
Dimensions as drawn
A 4500 mm
B 600 mm
C 462 mm
F 650 mm
G 700 mm
E 1815 mm
D IN 1 x Ø15,9
D OUT 1 x Ø28
Overall [mm]
Length 4500 mm
Width 600 mm
Height 462 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.