- Catalogue
- Khufu ModularRack
- Khufu ModularRack HT
Khufu ModularRack HT
- Application
- High temperature (HT)
- Refrigerants
- R1234yf, R1234ze(E), R134a, R22, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454C, R455A, R507A, R513A, R515B
- Capacity
- 101.88–768.24 kW
| Model | Refrigerating capacity [kW] i | Absorbed power [kW] | COP | Compressors | Receiver [l] | Max. current [A] | Compare |
|---|---|---|---|---|---|---|---|
| BKMR-2P-S25-63Y-F-B | 101.88 kW Power 35.85 kW COP 2.84 | 35.85 | 2.84 | 2 × semi-hermetic reciprocating compressors | 60 | 79.0 | Compare |
| BKMR-2P-S25-63Y-F-C | 101.88 kW Power 35.85 kW COP 2.84 | 35.85 | 2.84 | 2 × semi-hermetic reciprocating compressors | 60 | 79.0 | Compare |
| BKMR-2P-4MA-22X | 104.10 kW Power 31.50 kW COP 3.30 | 31.50 | 3.30 | 2 × semi-hermetic reciprocating compressors | 60 | 59.4 | Compare |
| BKMR-2P-4JE-22Y | 104.40 kW Power 32.70 kW COP 3.19 | 32.70 | 3.19 | 2 × semi-hermetic reciprocating compressors | 60 | 65.0 | Compare |
| BKMR-2P-V25-71Y-F-B | 114.98 kW Power 38.23 kW COP 3.01 | 38.23 | 3.01 | 2 × semi-hermetic reciprocating compressors | 60 | 87.0 | Compare |
| BKMR-2P-V25-71Y-F-C | 114.98 kW Power 38.23 kW COP 3.01 | 38.23 | 3.01 | 2 × semi-hermetic reciprocating compressors | 60 | 87.0 | Compare |
| BKMR-2P-4HE-25Y | 122.30 kW Power 38.70 kW COP 3.16 | 38.70 | 3.16 | 2 × semi-hermetic reciprocating compressors | 60 | 77.6 | Compare |
| BKMR-2P-4MH-25X | 123.90 kW Power 37.40 kW COP 3.31 | 37.40 | 3.31 | 2 × semi-hermetic reciprocating compressors | 60 | 76.8 | Compare |
| BKMR-2P-4MI-30X | 134.30 kW Power 41.30 kW COP 3.25 | 41.30 | 3.25 | 2 × semi-hermetic reciprocating compressors | 120 | 91.6 | Compare |
| BKMR-2P-V30-84Y-F-B | 138.03 kW Power 45.09 kW COP 3.06 | 45.09 | 3.06 | 2 × semi-hermetic reciprocating compressors | 120 | 98.4 | Compare |
| BKMR-2P-V30-84Y-F-C | 138.03 kW Power 45.09 kW COP 3.06 | 45.09 | 3.06 | 2 × semi-hermetic reciprocating compressors | 120 | 98.4 | Compare |
| BKMR-2P-4GE-30Y | 140.00 kW Power 44.70 kW COP 3.13 | 44.70 | 3.13 | 2 × semi-hermetic reciprocating compressors | 120 | 90.6 | Compare |
| BKMR-3P-S25-63Y-F-B | 152.83 kW Power 53.78 kW COP 2.84 | 53.78 | 2.84 | 3 × semi-hermetic reciprocating compressors | 150 | 118.5 | Compare |
| BKMR-3P-S25-63Y-F-C | 152.83 kW Power 53.78 kW COP 2.84 | 53.78 | 2.84 | 3 × semi-hermetic reciprocating compressors | 150 | 118.5 | Compare |
| BKMR-3P-4MA-22X | 156.20 kW Power 47.20 kW COP 3.31 | 47.20 | 3.31 | 3 × semi-hermetic reciprocating compressors | 150 | 89.1 | Compare |
| BKMR-3P-4JE-22Y | 156.60 kW Power 49.00 kW COP 3.20 | 49.00 | 3.20 | 3 × semi-hermetic reciprocating compressors | 150 | 97.5 | Compare |
| BKMR-2P-4FE-35Y | 166.13 kW Power 55.40 kW COP 3.00 | 55.40 | 3.00 | 2 × semi-hermetic reciprocating compressors | 150 | 110.7 | Compare |
| BKMR-2P-4MK-35X | 171.00 kW Power 53.93 kW COP 3.17 | 53.93 | 3.17 | 2 × semi-hermetic reciprocating compressors | 150 | 105.3 | Compare |
| BKMR-2PH-V35-112Y-F-B | 171.67 kW Power 65.02 kW COP 2.64 | 65.02 | 2.64 | 2 × semi-hermetic reciprocating compressors | 150 | 135.0 | Compare |
| BKMR-2PH-V35-112Y-F-C | 171.67 kW Power 65.02 kW COP 2.64 | 65.02 | 2.64 | 2 × semi-hermetic reciprocating compressors | 150 | 135.0 | Compare |
| BKMR-3P-V25-71Y-F-B | 172.48 kW Power 57.34 kW COP 3.01 | 57.34 | 3.01 | 3 × semi-hermetic reciprocating compressors | 150 | 130.5 | Compare |
| BKMR-3P-V25-71Y-F-C | 172.48 kW Power 57.34 kW COP 3.01 | 57.34 | 3.01 | 3 × semi-hermetic reciprocating compressors | 150 | 130.5 | Compare |
| BKMR-3P-4HE-25Y | 183.40 kW Power 58.00 kW COP 3.16 | 58.00 | 3.16 | 3 × semi-hermetic reciprocating compressors | 150 | 116.4 | Compare |
| BKMR-3P-4MH-25X | 185.80 kW Power 56.10 kW COP 3.31 | 56.10 | 3.31 | 3 × semi-hermetic reciprocating compressors | 150 | 115.3 | Compare |
| BKMR-3P-4MI-30X | 201.40 kW Power 62.00 kW COP 3.25 | 62.00 | 3.25 | 3 × semi-hermetic reciprocating compressors | 150 | 137.3 | Compare |
| BKMR-2P-6GE-40Y | 202.93 kW Power 66.07 kW COP 3.07 | 66.07 | 3.07 | 2 × semi-hermetic reciprocating compressors | 150 | 134.5 | Compare |
| BKMR-4P-S25-63Y-F-B | 203.77 kW Power 71.70 kW COP 2.84 | 71.70 | 2.84 | 4 × semi-hermetic reciprocating compressors | 150 | 158.0 | Compare |
| BKMR-4P-S25-63Y-F-C | 203.77 kW Power 71.70 kW COP 2.84 | 71.70 | 2.84 | 4 × semi-hermetic reciprocating compressors | 150 | 158.0 | Compare |
| BKMR-2PH-Z40-126Y-F-B | 205.23 kW Power 65.08 kW COP 3.15 | 65.08 | 3.15 | 2 × semi-hermetic reciprocating compressors | 150 | 143.8 | Compare |
| BKMR-2PH-Z40-126Y-F-C | 205.23 kW Power 65.08 kW COP 3.15 | 65.08 | 3.15 | 2 × semi-hermetic reciprocating compressors | 150 | 143.8 | Compare |
| BKMR-2P-6MI-40X | 206.13 kW Power 63.60 kW COP 3.24 | 63.60 | 3.24 | 2 × semi-hermetic reciprocating compressors | 150 | 112.9 | Compare |
| BKMR-3P-V30-84Y-F-B | 207.05 kW Power 67.63 kW COP 3.06 | 67.63 | 3.06 | 3 × semi-hermetic reciprocating compressors | 150 | 147.6 | Compare |
| BKMR-3P-V30-84Y-F-C | 207.05 kW Power 67.63 kW COP 3.06 | 67.63 | 3.06 | 3 × semi-hermetic reciprocating compressors | 150 | 147.6 | Compare |
| BKMR-4P-4MA-22X | 208.20 kW Power 63.00 kW COP 3.30 | 63.00 | 3.30 | 4 × semi-hermetic reciprocating compressors | 150 | 118.8 | Compare |
| BKMR-4P-4JE-22Y | 208.80 kW Power 65.40 kW COP 3.19 | 65.40 | 3.19 | 4 × semi-hermetic reciprocating compressors | 150 | 130.0 | Compare |
| BKMR-3P-4GE-30Y | 210.00 kW Power 67.10 kW COP 3.13 | 67.10 | 3.13 | 3 × semi-hermetic reciprocating compressors | 150 | 136.0 | Compare |
| BKMR-4P-V25-71Y-F-B | 229.97 kW Power 76.46 kW COP 3.01 | 76.46 | 3.01 | 4 × semi-hermetic reciprocating compressors | 150 | 174.0 | Compare |
| BKMR-4P-V25-71Y-F-C | 229.97 kW Power 76.46 kW COP 3.01 | 76.46 | 3.01 | 4 × semi-hermetic reciprocating compressors | 150 | 174.0 | Compare |
| BKMR-4P-4HE-25Y | 244.50 kW Power 77.30 kW COP 3.16 | 77.30 | 3.16 | 4 × semi-hermetic reciprocating compressors | 150 | 155.2 | Compare |
| BKMR-2P-6FE-50Y | 246.67 kW Power 82.07 kW COP 3.01 | 82.07 | 3.01 | 2 × semi-hermetic reciprocating compressors | 150 | 174.8 | Compare |
| BKMR-4P-4MH-25X | 247.70 kW Power 74.80 kW COP 3.31 | 74.80 | 3.31 | 4 × semi-hermetic reciprocating compressors | 150 | 153.7 | Compare |
| BKMR-3P-4FE-35Y | 249.20 kW Power 83.10 kW COP 3.00 | 83.10 | 3.00 | 3 × semi-hermetic reciprocating compressors | 250 | 166.1 | Compare |
| BKMR-2P-Z50-154Y-F-B | 249.32 kW Power 82.97 kW COP 3.00 | 82.97 | 3.00 | 2 × semi-hermetic reciprocating compressors | 150 | 180.8 | Compare |
| BKMR-2P-Z50-154Y-F-C | 249.32 kW Power 82.97 kW COP 3.00 | 82.97 | 3.00 | 2 × semi-hermetic reciprocating compressors | 150 | 180.8 | Compare |
| BKMR-5P-S25-63Y-F-B | 254.71 kW Power 89.63 kW COP 2.84 | 89.63 | 2.84 | 5 × semi-hermetic reciprocating compressors | 150 | 197.5 | Compare |
| BKMR-5P-S25-63Y-F-C | 254.71 kW Power 89.63 kW COP 2.84 | 89.63 | 2.84 | 5 × semi-hermetic reciprocating compressors | 150 | 197.5 | Compare |
| BKMR-2P-6MK-50X | 256.07 kW Power 83.00 kW COP 3.09 | 83.00 | 3.09 | 2 × semi-hermetic reciprocating compressors | 150 | 165.1 | Compare |
| BKMR-3P-4MK-35X | 256.50 kW Power 80.90 kW COP 3.17 | 80.90 | 3.17 | 3 × semi-hermetic reciprocating compressors | 250 | 157.9 | Compare |
| BKMR-3PH-V35-112Y-F-B | 257.50 kW Power 97.53 kW COP 2.64 | 97.53 | 2.64 | 3 × semi-hermetic reciprocating compressors | 250 | 202.5 | Compare |
| BKMR-3PH-V35-112Y-F-C | 257.50 kW Power 97.53 kW COP 2.64 | 97.53 | 2.64 | 3 × semi-hermetic reciprocating compressors | 250 | 202.5 | Compare |
Nominal conditions: evaporating 2 °C, condensing 45 °C (dew points), superheat 10 K, subcooling 3 K; refrigerant R404A where rated.
Downloads
- BKMR-2P-S25-63Y-F-B — product datasheet (PDF)
- BKMR-2P-S25-63Y-F-C — product datasheet (PDF)
- BKMR-2P-4MA-22X — product datasheet (PDF)
- BKMR-2P-4JE-22Y — product datasheet (PDF)
- BKMR-2P-V25-71Y-F-B — product datasheet (PDF)
- BKMR-2P-V25-71Y-F-C — product datasheet (PDF)
- BKMR-2P-4HE-25Y — product datasheet (PDF)
- BKMR-2P-4MH-25X — product datasheet (PDF)
- BKMR-2P-4MI-30X — product datasheet (PDF)
- BKMR-2P-V30-84Y-F-B — product datasheet (PDF)
- BKMR-2P-V30-84Y-F-C — product datasheet (PDF)
- BKMR-2P-4GE-30Y — product datasheet (PDF)
- BKMR-3P-S25-63Y-F-B — product datasheet (PDF)
- BKMR-3P-S25-63Y-F-C — product datasheet (PDF)
- BKMR-3P-4MA-22X — product datasheet (PDF)
- BKMR-3P-4JE-22Y — product datasheet (PDF)
- BKMR-2P-4FE-35Y — product datasheet (PDF)
- BKMR-2P-4MK-35X — product datasheet (PDF)
- BKMR-2PH-V35-112Y-F-B — product datasheet (PDF)
- BKMR-2PH-V35-112Y-F-C — product datasheet (PDF)
- BKMR-3P-V25-71Y-F-B — product datasheet (PDF)
- BKMR-3P-V25-71Y-F-C — product datasheet (PDF)
- BKMR-3P-4HE-25Y — product datasheet (PDF)
- BKMR-3P-4MH-25X — product datasheet (PDF)
- BKMR-3P-4MI-30X — product datasheet (PDF)
- BKMR-2P-6GE-40Y — product datasheet (PDF)
- BKMR-4P-S25-63Y-F-B — product datasheet (PDF)
- BKMR-4P-S25-63Y-F-C — product datasheet (PDF)
- BKMR-2PH-Z40-126Y-F-B — product datasheet (PDF)
- BKMR-2PH-Z40-126Y-F-C — product datasheet (PDF)
- BKMR-2P-6MI-40X — product datasheet (PDF)
- BKMR-3P-V30-84Y-F-B — product datasheet (PDF)
- BKMR-3P-V30-84Y-F-C — product datasheet (PDF)
- BKMR-4P-4MA-22X — product datasheet (PDF)
- BKMR-4P-4JE-22Y — product datasheet (PDF)
- BKMR-3P-4GE-30Y — product datasheet (PDF)
- BKMR-4P-V25-71Y-F-B — product datasheet (PDF)
- BKMR-4P-V25-71Y-F-C — product datasheet (PDF)
- BKMR-4P-4HE-25Y — product datasheet (PDF)
- BKMR-2P-6FE-50Y — product datasheet (PDF)
- BKMR-4P-4MH-25X — product datasheet (PDF)
- BKMR-3P-4FE-35Y — product datasheet (PDF)
- BKMR-2P-Z50-154Y-F-B — product datasheet (PDF)
- BKMR-2P-Z50-154Y-F-C — product datasheet (PDF)
- BKMR-5P-S25-63Y-F-B — product datasheet (PDF)
- BKMR-5P-S25-63Y-F-C — product datasheet (PDF)
- BKMR-2P-6MK-50X — product datasheet (PDF)
- BKMR-3P-4MK-35X — product datasheet (PDF)
- BKMR-3PH-V35-112Y-F-B — product datasheet (PDF)
- BKMR-3PH-V35-112Y-F-C — product datasheet (PDF)
Ask about product
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.