EA-230AC7-C01 C
3.66 kW
Defrost: None
Product code: EA-230AC6-C05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,225 m³/h |
|---|---|
| Air throw | 6 m |
| External surface | 14.5 m² |
| Inner volume | 3.9 dm³ |
| Fin spacing | 6.0 mm |
| Fin material | Aluminium |
| Net weight | 26 kg |
| Quantity | 2 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 240 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 44.0 dB(A) |
|---|---|
| Sound power | 65.0 dB(A) |
| Energy class | D |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø22 |
| EA-230AC6-C05 C | None |
|---|---|
| EA-230AC6-C05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 1.40 | 1.37 | 1.35 | 1.34 | 1.34 | 1.33 | 1.31 | 1.35 | 1.43 | 1.55 | 1.52 | 1.51 | 1.49 | 1.47 |
| 5 | 1.89 | 1.86 | 1.84 | 1.83 | 1.82 | 1.80 | 1.78 | 1.81 | 1.92 | 2.08 | 2.03 | 2.01 | 1.99 | 1.97 |
| 6 | 2.40 | 2.38 | 2.37 | 2.37 | 2.35 | 2.33 | 2.30 | 2.32 | 2.46 | 2.66 | 2.58 | 2.55 | 2.52 | 2.47 |
| 7 | 2.90 | 2.91 | 2.92 | 2.93 | 2.92 | 2.90 | 2.86 | 2.88 | 3.04 | 3.29 | 3.17 | 3.14 | 3.08 | 2.99 |
| 8 | 3.41 | 3.44 | 3.48 | 3.51 | 3.52 | 3.50 | 3.46 | 3.47 | 3.67 | 3.96 | 3.81 | 3.76 | 3.68 | 3.56 |
| 9 | 3.89 | 3.97 | 4.04 | 4.10 | 4.13 | 4.12 | 4.08 | 4.09 | 4.32 | 4.66 | 4.49 | 4.42 | 4.33 | 4.17 |
| 10 | 4.32 | 4.44 | 4.55 | 4.66 | 4.72 | 4.74 | 4.71 | 4.72 | 4.99 | 5.38 | 5.20 | 5.12 | 5.00 | 4.81 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 5.200 |
| SC2 | 0 | 8 | 3.468 |
| SC3 | -18 | 7 | 2.931 |
| SC4 | -25 | 6 | 2.367 |
| SC5 | -34 | 6 | 2.395 |
| A | 1157 mm |
|---|---|
| B | 517 mm |
| C | 445 mm |
| F | 345 mm |
| E1 | 417.5 mm |
| E | 835 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø22 |
| Length | 1157 mm |
|---|---|
| Width | 517 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.