EA-240AE6-C01 C
11.81 kW
Defrost: None
Product code: EA-335AE8-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 6,648 m³/h |
|---|---|
| Air throw | 11 m |
| External surface | 38.1 m² |
| Inner volume | 14.5 dm³ |
| Fin spacing | 8.0 mm |
| Fin material | Aluminium |
| Net weight | 78 kg |
| Quantity | 3 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 495 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø28 |
| EA-335AE8-C01 C | None |
|---|---|
| EA-335AE8-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.36 | 4.41 | 4.45 | 4.50 | 4.50 | 4.48 | 4.43 | 4.55 | 4.85 | 5.25 | 5.12 | 5.08 | 5.01 | 4.91 |
| 5 | 5.66 | 5.81 | 5.95 | 6.08 | 6.13 | 6.13 | 6.09 | 6.20 | 6.59 | 7.14 | 6.95 | 6.88 | 6.79 | 6.67 |
| 6 | 6.92 | 7.21 | 7.47 | 7.69 | 7.81 | 7.86 | 7.83 | 7.95 | 8.44 | 9.14 | 8.87 | 8.77 | 8.62 | 8.39 |
| 7 | 8.05 | 8.48 | 8.87 | 9.22 | 9.46 | 9.60 | 9.63 | 9.73 | 10.33 | 11.21 | 10.90 | 10.77 | 10.58 | 10.26 |
| 8 | 9.02 | 9.59 | 10.12 | 10.54 | 10.87 | 11.08 | 11.19 | 11.37 | 12.09 | 13.15 | 12.85 | 12.72 | 12.52 | 12.19 |
| 9 | 9.90 | 10.64 | 11.25 | 11.85 | 12.28 | 12.57 | 12.73 | 12.95 | 13.78 | 14.98 | 14.66 | 14.51 | 14.28 | 13.88 |
| 10 | 10.70 | 11.53 | 12.37 | 13.11 | 13.67 | 14.05 | 14.27 | 14.54 | 15.47 | 16.82 | 16.48 | 16.31 | 16.05 | 15.59 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 16.482 |
| SC2 | 0 | 8 | 11.369 |
| SC3 | -18 | 7 | 9.326 |
| SC4 | -25 | 6 | 7.469 |
| SC5 | -34 | 6 | 6.991 |
| A | 1857 mm |
|---|---|
| B | 573 mm |
| C | 525 mm |
| F | 395 mm |
| E1 | 517.5 mm |
| E2 | 500 mm |
| E | 1535 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø28 |
| Length | 1857 mm |
|---|---|
| Width | 573 mm |
| Height | 525 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.