EB-135AC6-B01 C
3.93 kW
Defrost: None
Product code: EB-230BC7-B05 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,524 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 12.4 m² |
| Inner volume | 3.5 dm³ |
| Fin spacing | 7.0 mm |
| Fin material | Aluminium |
| Net weight | 32 kg |
| Quantity | 2 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,300 rpm |
| Power | 240 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 43.0 dB(A) |
|---|---|
| Sound power | 65.0 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø22 |
| EB-230BC7-B05 C | None |
|---|---|
| EB-230BC7-B05 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 1.47 | 1.44 | 1.43 | 1.43 | 1.42 | 1.41 | 1.40 | 1.42 | 1.51 | 1.63 | 1.60 | 1.59 | 1.57 | 1.54 |
| 5 | 1.97 | 1.95 | 1.94 | 1.94 | 1.94 | 1.92 | 1.90 | 1.93 | 2.04 | 2.21 | 2.15 | 2.14 | 2.11 | 2.07 |
| 6 | 2.48 | 2.47 | 2.48 | 2.50 | 2.50 | 2.48 | 2.46 | 2.48 | 2.63 | 2.84 | 2.76 | 2.73 | 2.69 | 2.63 |
| 7 | 2.98 | 3.00 | 3.03 | 3.07 | 3.08 | 3.08 | 3.05 | 3.07 | 3.25 | 3.51 | 3.41 | 3.37 | 3.31 | 3.21 |
| 8 | 3.46 | 3.52 | 3.58 | 3.64 | 3.68 | 3.68 | 3.67 | 3.69 | 3.90 | 4.22 | 4.10 | 4.04 | 3.97 | 3.85 |
| 9 | 3.90 | 3.99 | 4.09 | 4.19 | 4.26 | 4.30 | 4.30 | 4.32 | 4.58 | 4.95 | 4.81 | 4.75 | 4.66 | 4.51 |
| 10 | 4.30 | 4.44 | 4.57 | 4.70 | 4.79 | 4.84 | 4.87 | 4.92 | 5.22 | 5.66 | 5.53 | 5.47 | 5.37 | 5.19 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 5.531 |
| SC2 | 0 | 8 | 3.686 |
| SC3 | -18 | 7 | 3.074 |
| SC4 | -25 | 6 | 2.481 |
| SC5 | -34 | 6 | 2.478 |
| A | 1357 mm |
|---|---|
| B | 520 mm |
| C | 426 mm |
| F | 345 mm |
| E1 | 518 mm |
| E | 1035 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø22 |
| Length | 1357 mm |
|---|---|
| Width | 520 mm |
| Height | 426 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.