EG-335CG4-C21 C
13.31 kW
Defrost: None
Product code: EG-335BE4-C21 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,884 m³/h |
|---|---|
| Air throw | 18 m |
| External surface | 51.6 m² |
| Inner volume | 9.0 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 59 kg |
| Quantity | 3 |
|---|---|
| Diameter | 350 mm |
| Speed | 1,340 rpm |
| Power | 495 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 53.0 dB(A) |
|---|---|
| Sound power | 75.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø28 |
| EG-335BE4-C21 C | None |
|---|---|
| EG-335BE4-C21 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5.13 | 5.20 | 5.28 | 5.35 | 5.37 | 5.36 | 5.31 | 5.48 | 5.85 | 6.36 | 6.24 | 6.21 | 6.16 | 6.10 |
| 5 | 6.60 | 6.79 | 6.97 | 7.12 | 7.20 | 7.20 | 7.14 | 7.30 | 7.76 | 8.43 | 8.20 | 8.12 | 8.01 | 7.85 |
| 6 | 7.91 | 8.22 | 8.52 | 8.79 | 8.95 | 9.03 | 9.03 | 9.21 | 9.79 | 10.63 | 10.30 | 10.18 | 10.00 | 9.70 |
| 7 | 9.16 | 9.61 | 9.97 | 10.35 | 10.59 | 10.71 | 10.73 | 10.90 | 11.58 | 12.58 | 12.24 | 12.10 | 11.89 | 11.54 |
| 8 | 10.27 | 10.87 | 11.43 | 11.92 | 12.24 | 12.39 | 12.44 | 12.63 | 13.40 | 14.54 | 14.15 | 13.98 | 13.71 | 13.26 |
| 9 | 11.29 | 12.07 | 12.79 | 13.42 | 13.85 | 14.09 | 14.17 | 14.35 | 15.22 | 16.50 | 16.07 | 15.86 | 15.55 | 15.01 |
| 10 | 12.22 | 13.20 | 14.10 | 14.89 | 15.35 | 15.69 | 15.84 | 16.09 | 17.08 | 18.51 | 18.04 | 17.80 | 17.44 | 16.80 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 18.037 |
| SC2 | 0 | 8 | 12.626 |
| SC3 | -18 | 7 | 10.456 |
| SC4 | -25 | 6 | 8.520 |
| SC5 | -34 | 6 | 7.988 |
| A | 2972 mm |
|---|---|
| B | 685 mm |
| C | 338 mm |
| F | 630 mm |
| E1 | 893 mm |
| E2 | 875 mm |
| E | 2260 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø28 |
| Length | 2972 mm |
|---|---|
| Width | 685 mm |
| Height | 338 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.