EG-330AC4-C25 C
6.12 kW
Defrost: None
Product code: EG-425BE4-C23 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 2,249 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 35.4 m² |
| Inner volume | 6.1 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 47 kg |
| Quantity | 4 |
|---|---|
| Diameter | 250 mm |
| Speed | 1,300 rpm |
| Power | 260 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 43.0 dB(A) |
|---|---|
| Sound power | 64.4 dB(A) |
| Energy class | D |
| Inlet | Ø12,7 |
|---|---|
| Outlet | Ø22 |
| EG-425BE4-C23 C | None |
|---|---|
| EG-425BE4-C23 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 2.44 | 2.52 | 2.59 | 2.67 | 2.71 | 2.73 | 2.73 | 2.80 | 2.99 | 3.25 | 3.19 | 3.17 | 3.14 | 3.09 |
| 5 | 3.02 | 3.16 | 3.30 | 3.42 | 3.49 | 3.53 | 3.54 | 3.61 | 3.84 | 4.17 | 4.07 | 4.03 | 3.97 | 3.87 |
| 6 | 3.56 | 3.77 | 3.97 | 4.14 | 4.26 | 4.33 | 4.36 | 4.43 | 4.71 | 5.12 | 4.99 | 4.94 | 4.85 | 4.71 |
| 7 | 4.05 | 4.32 | 4.58 | 4.82 | 4.98 | 5.08 | 5.13 | 5.21 | 5.54 | 6.02 | 5.89 | 5.82 | 5.73 | 5.55 |
| 8 | 4.53 | 4.88 | 5.21 | 5.49 | 5.69 | 5.82 | 5.89 | 5.99 | 6.37 | 6.91 | 6.76 | 6.69 | 6.57 | 6.36 |
| 9 | ≈ 4.93 | 5.36 | 5.77 | 6.13 | 6.39 | 6.57 | 6.66 | 6.77 | 7.19 | 7.81 | 7.64 | 7.54 | 7.41 | 7.17 |
| 10 | ≈ 5.30 | 5.81 | 6.30 | 6.75 | 7.07 | 7.29 | 7.39 | 7.52 | 8.00 | 8.69 | 8.50 | 8.41 | 8.26 | 7.99 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 8.504 |
| SC2 | 0 | 8 | 5.989 |
| SC3 | -18 | 7 | 4.888 |
| SC4 | -25 | 6 | 3.966 |
| SC5 | -34 | 6 | 3.613 |
| A | 1786 mm |
|---|---|
| B | 685 mm |
| C | 370 mm |
| F | 630 mm |
| E1 | 378 mm |
| E2 | 360 mm |
| E | 1475 mm |
| D IN | 1 x Ø12,7 |
| D OUT | 1 x Ø22 |
| Length | 1786 mm |
|---|---|
| Width | 685 mm |
| Height | 370 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.