Skip to Content

Unit cooler EL-212BE4-C21 C

Unit cooler EL-212BE4-C21 C
Illustrative photo

Producer: Karyer · Line: EL (Under Counter)

Product code: EL-212BE4-C21 C

Cooling capacity i
0.37 kW
Air flow
143 m³/h
Fin spacing
4.2 mm
Air throw
1 m
Fans
2 × ⌀120 mm

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Model nomenclature

How to read the code of this model.

  • A
    Model code (series): EL — EL - under-counter cooler
  • B
    Number of fans: 2 — Number of fans (one digit).
  • C
    Fan diameter: 12 — Ø120 mm
  • D
    Dimensional data - coil size letter: B — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows: E — 6 tube rows
  • F
    Fin spacing: 4 — Fin spacing about 4 mm
  • G
    Generation code: C — Generation C
  • H
    Fan data: 21 — Ø120: 230V/1Ph/50Hz, 4-pole

Data

Evaporator
Air flow 143 m³/h
Air throw 1 m
External surface 2.0 m²
Inner volume 0.3 dm³
Fin spacing 4.2 mm
Fin materialAluminium
Net weight 4 kg
Fans
Quantity 2
Diameter 120 mm
Speed 2,600 rpm
Power 36 W
Supply 230V/1Ph/50Hz
Motor type AC
Poles 4
Acoustic
Sound pressure 25.0 dB(A)
Sound power 46.0 dB(A)
Energy class E
Connections
Inlet Ø1/4"
Outlet Ø1/4"
Defrost
EL-212BE4-C21 C None
EL-212BE4-C21 C ED Electric

Performance

No glide: dew, mid and bubble point give the same rating.

TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.

R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)

Single phase
0.361 kW

Capacity matrix [kW]

R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.

Single phase

Cooling capacity [kW] per air inlet temperature and TD
TD [K] \ air [°C] -35-30-25-20-15-10-502510121520
4 0.15 0.15 0.16 0.16 0.16 0.16 0.16 0.16 0.18 0.19 0.19 0.19 0.18 0.18
5 0.19 0.20 0.20 0.20 0.21 0.21 0.21 0.21 0.23 0.24 0.24 0.24 0.23 0.23
6 0.23 0.24 0.24 0.25 0.26 0.26 0.26 0.26 0.28 0.30 0.29 0.29 0.28 0.28
7 0.27 0.28 0.29 0.30 0.30 0.31 0.31 0.31 0.33 0.36 0.35 0.34 0.34 0.33
8 0.30 0.32 0.33 0.34 0.35 0.35 0.36 0.36 0.38 0.41 0.40 0.40 0.39 0.38
9 0.33 0.35 0.37 0.38 0.39 0.40 0.40 0.41 0.43 0.47 0.46 0.45 0.45 0.43
10 0.36 0.39 0.41 0.43 0.44 0.45 0.45 0.46 0.48 0.52 0.51 0.51 0.50 0.48

Standard ratings (EN 328 / Eurovent)

Standard condition Air inlet [°C] TD [K] Single phase [kW]
SC1 10 10 0.512
SC2 0 8 0.361
SC3 -18 7 0.300
SC4 -25 6 0.244
SC5 -34 6 0.232

Dimensions

Dimension drawing of EL-212BE4-C21 C
Dimension drawing
Dimensions as drawn
A 480 mm
B 465 mm
C 80 mm
E 490 mm
D 465 mm
D IN 1 x Ø1/4"
D OUT 1 x Ø1/4"
Overall [mm]
Length 490 mm
Width 80 mm
Height 480 mm

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.