EA-530AE4-C05 C
12.15 kW
Defrost: None
Product code: EA-340AC8-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 9,850 m³/h |
|---|---|
| Air throw | 14 m |
| External surface | 32.6 m² |
| Inner volume | 12.7 dm³ |
| Fin spacing | 8.0 mm |
| Fin material | Aluminium |
| Net weight | 81 kg |
| Quantity | 3 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 63.0 dB(A) |
|---|---|
| Sound power | 85.0 dB(A) |
| Energy class | C |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø35 |
| EA-340AC8-C01 C | None |
|---|---|
| EA-340AC8-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 4.34 | 4.27 | 4.23 | 4.20 | 4.16 | 4.11 | 4.05 | 4.08 | 4.31 | 4.65 | 4.52 | 4.47 | 4.41 | 4.31 |
| 5 | 5.87 | 5.86 | 5.87 | 5.88 | 5.85 | 5.80 | 5.72 | 5.75 | 6.09 | 6.57 | 6.38 | 6.32 | 6.22 | 6.07 |
| 6 | 7.41 | 7.48 | 7.58 | 7.67 | 7.69 | 7.65 | 7.58 | 7.61 | 8.06 | 8.70 | 8.42 | 8.33 | 8.19 | 7.99 |
| 7 | 8.86 | 9.09 | 9.31 | 9.50 | 9.59 | 9.60 | 9.55 | 9.60 | 10.17 | 10.98 | 10.64 | 10.51 | 10.32 | 10.03 |
| 8 | 10.14 | 10.50 | 10.85 | 11.17 | 11.38 | 11.52 | 11.56 | 11.65 | 12.34 | 13.36 | 12.98 | 12.83 | 12.61 | 12.24 |
| 9 | 11.28 | 11.80 | 12.27 | 12.66 | 12.96 | 13.16 | 13.27 | 13.42 | 14.26 | 15.50 | 15.16 | 15.03 | 14.82 | 14.47 |
| 10 | 12.36 | 12.97 | 13.59 | 14.16 | 14.56 | 14.83 | 14.99 | 15.18 | 16.13 | 17.53 | 17.17 | 17.01 | 16.78 | 16.38 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 17.170 |
| SC2 | 0 | 8 | 11.649 |
| SC3 | -18 | 7 | 9.548 |
| SC4 | -25 | 6 | 7.577 |
| SC5 | -34 | 6 | 7.443 |
| A | 2017 mm |
|---|---|
| B | 586 mm |
| C | 605 mm |
| F | 395 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 1685 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø35 |
| Length | 2017 mm |
|---|---|
| Width | 586 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.