EA-163EG4-C01 C
17.10 kW
Defrost: None
Product code: EA-340AG10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 8,247 m³/h |
|---|---|
| Air throw | 12 m |
| External surface | 53.6 m² |
| Inner volume | 24.5 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 117 kg |
| Quantity | 3 |
|---|---|
| Diameter | 400 mm |
| Speed | 1,430 rpm |
| Power | 480 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 63.0 dB(A) |
|---|---|
| Sound power | 85.0 dB(A) |
| Energy class | B |
| Inlet | Ø22 |
|---|---|
| Outlet | Ø42 |
| EA-340AG10-C01 C | None |
|---|---|
| EA-340AG10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 6.59 | 6.56 | 6.57 | 6.59 | 6.56 | 6.51 | 6.42 | 6.60 | 7.03 | 7.63 | 7.47 | 7.42 | 7.32 | 7.18 |
| 5 | 8.61 | 8.69 | 8.78 | 8.87 | 8.89 | 8.84 | 8.73 | 8.89 | 9.44 | 10.22 | 9.93 | 9.83 | 9.69 | 9.51 |
| 6 | 10.56 | 10.79 | 11.01 | 11.21 | 11.30 | 11.28 | 11.18 | 11.31 | 11.99 | 12.98 | 12.55 | 12.39 | 12.16 | 11.79 |
| 7 | 12.49 | 12.87 | 13.24 | 13.54 | 13.72 | 13.77 | 13.70 | 13.82 | 14.64 | 15.85 | 15.32 | 15.11 | 14.79 | 14.26 |
| 8 | 14.23 | 14.83 | 15.39 | 15.87 | 16.17 | 16.28 | 16.23 | 16.39 | 17.36 | 18.78 | 18.19 | 17.93 | 17.54 | 16.88 |
| 9 | 15.79 | 16.58 | 17.32 | 17.98 | 18.40 | 18.64 | 18.68 | 18.92 | 20.08 | 21.71 | 21.07 | 20.77 | 20.32 | 19.54 |
| 10 | 17.21 | 18.23 | 19.17 | 19.90 | 20.47 | 20.82 | 20.95 | 21.24 | 22.54 | 24.43 | 23.82 | 23.52 | 23.06 | 22.24 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 23.820 |
| SC2 | 0 | 8 | 16.387 |
| SC3 | -18 | 7 | 13.631 |
| SC4 | -25 | 6 | 11.008 |
| SC5 | -34 | 6 | 10.622 |
| A | 2017 mm |
|---|---|
| B | 686 mm |
| C | 605 mm |
| F | 495 mm |
| E1 | 568 mm |
| E2 | 550 mm |
| E | 1685 mm |
| D IN | 1 x Ø22 |
| D OUT | 1 x Ø42 |
| Length | 2017 mm |
|---|---|
| Width | 686 mm |
| Height | 605 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.