EG-130AE4-C21 C
2.70 kW
Defrost: Electric
Product code: EG-225BC4-C23 C ED
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 1,291 m³/h |
|---|---|
| Air throw | 7 m |
| External surface | 11.8 m² |
| Inner volume | 2.1 dm³ |
| Fin spacing | 4.2 mm |
| Fin material | Aluminium |
| Net weight | 25 kg |
| Quantity | 2 |
|---|---|
| Diameter | 250 mm |
| Speed | 1,300 rpm |
| Power | 130 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 40.0 dB(A) |
|---|---|
| Sound power | 61.4 dB(A) |
| Energy class | D |
| Inlet | Ø9,52 |
|---|---|
| Outlet | Ø12,7 |
| EG-225BC4-C23 C | None |
|---|---|
| EG-225BC4-C23 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 0.94 | 0.99 | 1.05 | 1.09 | 1.12 | 1.13 | 1.13 | 1.18 | 1.26 | 1.38 | 1.36 | 1.35 | 1.34 | 1.33 |
| 5 | 1.16 | 1.25 | 1.33 | 1.40 | 1.45 | 1.48 | 1.50 | 1.54 | 1.65 | 1.80 | 1.76 | 1.75 | 1.73 | 1.69 |
| 6 | 1.35 | 1.47 | 1.58 | 1.68 | 1.75 | 1.80 | 1.82 | 1.87 | 2.00 | 2.18 | 2.14 | 2.12 | 2.09 | 2.04 |
| 7 | ≈ 1.54 | 1.69 | 1.83 | 1.96 | 2.06 | 2.12 | 2.15 | 2.21 | 2.35 | 2.57 | 2.51 | 2.48 | 2.45 | 2.38 |
| 8 | ≈ 1.69 | 1.88 | 2.06 | 2.22 | 2.35 | 2.41 | 2.47 | 2.53 | 2.70 | 2.94 | 2.89 | 2.86 | 2.81 | 2.74 |
| 9 | ≈ 1.49 | ≈ 2.05 | 2.27 | 2.47 | 2.60 | 2.71 | 2.78 | 2.86 | 3.05 | 3.33 | 3.27 | 3.24 | 3.19 | 3.10 |
| 10 | ≈ 0.58 | ≈ 2.20 | 2.46 | 2.67 | 2.86 | 3.00 | 3.09 | 3.19 | 3.40 | 3.71 | 3.65 | 3.62 | 3.56 | 3.47 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 3.653 |
| SC2 | 0 | 8 | 2.531 |
| SC3 | -18 | 7 | 2.003 |
| SC4 | -25 | 6 | 1.581 |
| SC5 | -34 | 6 | 1.377 |
| A | 1066 mm |
|---|---|
| B | 685 mm |
| C | 370 mm |
| F | 630 mm |
| E1 | 378 mm |
| E | 755 mm |
| D IN | 1 x Ø9,52 |
| D OUT | 1 x Ø12,7 |
| Length | 1066 mm |
|---|---|
| Width | 685 mm |
| Height | 370 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.