EA-430AC4-C05 C
9.22 kW
Defrost: None
Product code: EA-430AE10-C01 C
Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %
How to read the code of this model.
| Air flow | 5,050 m³/h |
|---|---|
| Air throw | 8 m |
| External surface | 30.5 m² |
| Inner volume | 13.9 dm³ |
| Fin spacing | 10.0 mm |
| Fin material | Aluminium |
| Net weight | 71 kg |
| Quantity | 4 |
|---|---|
| Diameter | 300 mm |
| Speed | 1,380 rpm |
| Power | 248 W |
| Supply | 230V/1Ph/50Hz |
| Motor type | AC |
| Poles | 4 |
| Sound pressure | 48.0 dB(A) |
|---|---|
| Sound power | 70.3 dB(A) |
| Energy class | A |
| Inlet | Ø15,9 |
|---|---|
| Outlet | Ø28 |
| EA-430AE10-C01 C | None |
|---|---|
| EA-430AE10-C01 C ED | Electric |
TD (air − evaporating) must be within 4–10 K; air inlet −40…+20 °C.
R404A, dew point -8 °C, air inlet 0 °C (TD 8 K)
R404A, Dew point; rows: TD = air inlet − evaporating temperature, columns: air inlet temperature. The highlighted cell is the nominal point (SC2). "—": not rated by the manufacturer.
≈ 1.23 estimate — vendor data irregular here
| TD [K] \ air [°C] | -35 | -30 | -25 | -20 | -15 | -10 | -5 | 0 | 2 | 5 | 10 | 12 | 15 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3.50 | 3.48 | 3.49 | 3.50 | 3.50 | 3.48 | 3.45 | 3.51 | 3.73 | 4.04 | 3.96 | 3.93 | 3.88 | 3.80 |
| 5 | 4.57 | 4.61 | 4.66 | 4.72 | 4.74 | 4.72 | 4.69 | 4.75 | 5.04 | 5.46 | 5.31 | 5.26 | 5.19 | 5.09 |
| 6 | 5.61 | 5.73 | 5.85 | 5.96 | 6.02 | 6.03 | 6.01 | 6.06 | 6.43 | 6.96 | 6.76 | 6.69 | 6.58 | 6.40 |
| 7 | 6.64 | 6.84 | 7.04 | 7.20 | 7.32 | 7.37 | 7.36 | 7.43 | 7.88 | 8.53 | 8.29 | 8.19 | 8.05 | 7.81 |
| 8 | 7.57 | 7.89 | 8.18 | 8.45 | 8.62 | 8.72 | 8.73 | 8.82 | 9.35 | 10.14 | 9.87 | 9.75 | 9.58 | 9.29 |
| 9 | 8.42 | 8.84 | 9.23 | 9.59 | 9.84 | 10.00 | 10.07 | 10.21 | 10.83 | 11.74 | 11.46 | 11.33 | 11.13 | 10.79 |
| 10 | 9.18 | 9.72 | 10.22 | 10.62 | 10.95 | 11.17 | 11.30 | 11.46 | 12.18 | 13.24 | 12.97 | 12.84 | 12.64 | 12.30 |
| Standard condition | Air inlet [°C] | TD [K] | Single phase [kW] |
|---|---|---|---|
| SC1 | 10 | 10 | 12.970 |
| SC2 | 0 | 8 | 8.818 |
| SC3 | -18 | 7 | 7.256 |
| SC4 | -25 | 6 | 5.847 |
| SC5 | -34 | 6 | 5.643 |
| A | 2107 mm |
|---|---|
| B | 573 mm |
| C | 445 mm |
| F | 395 mm |
| E1 | 455 mm |
| E2 | 438 mm |
| E | 1785 mm |
| D IN | 1 x Ø15,9 |
| D OUT | 1 x Ø28 |
| Length | 2107 mm |
|---|---|
| Width | 573 mm |
| Height | 445 mm |
Our engineers answer with a selection for your conditions.
The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.