Skip to Content

EB (General)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.64–32.06 kW
Fans
⌀200, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450 mm
Max. working pressure
25 bar
EB (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EB = EB - economical unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • H
    Fan data 01 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole05 = Ø200: 230V/1Ph/50Hz, 4-pole; Ø250: 230V/1Ph/50Hz, 4-pole; Ø300: 230V/1Ph/50Hz, 4-pole07 = Ø450: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EB-235AE7-B01 C 9.79 kW 7.0 2 × ⌀350 12 5,011 None, Electric
Variants (2)
EB-430BC4-B01 C 9.85 kW 4.2 4 × ⌀300 8 5,325 None, Electric
Variants (2)
EB-240AC6-B01 C 9.96 kW 6.0 2 × ⌀400 14 6,916 None, Electric
Variants (2)
EB-430BE7-B05 C 10.21 kW 7.0 4 × ⌀300 7 4,515 None, Electric
Variants (2)
EB-430AE7-B01 C 10.25 kW 7.0 4 × ⌀300 7 4,745 None, Electric
Variants (2)
EB-235AE6-B01 C 10.40 kW 6.0 2 × ⌀350 12 4,928 None, Electric
Variants (2)
EB-430AE4-B01 C 10.67 kW 4.2 4 × ⌀300 7 4,384 None, Electric
Variants (2)
EB-430BE6-B05 C 10.71 kW 6.0 4 × ⌀300 7 4,408 None, Electric
Variants (2)
EB-335AC7-B01 C 10.82 kW 7.0 3 × ⌀350 13 8,118 None, Electric
Variants (2)
EB-430AE6-B01 C 10.83 kW 6.0 4 × ⌀300 7 4,644 None, Electric
Variants (2)
EB-245AC7-B01 C 11.03 kW 7.0 2 × ⌀450 17 10,405 None, Electric
Variants (2)
EB-240AC4-B01 C 11.14 kW 4.2 2 × ⌀400 13 6,683 None, Electric
Variants (2)
EB-245AC7-B07 C 11.19 kW 7.0 2 × ⌀450 18 10,814 None, Electric
Variants (2)
EB-430BE7-B01 C 11.20 kW 7.0 4 × ⌀300 8 5,123 None, Electric
Variants (2)
EB-430BE4-B05 C 11.33 kW 4.2 4 × ⌀300 7 4,134 None, Electric
Variants (2)
EB-235AE4-B01 C 11.40 kW 4.2 2 × ⌀350 11 4,678 None, Electric
Variants (2)
EB-335AC6-B01 C 11.51 kW 6.0 3 × ⌀350 13 8,021 None, Electric
Variants (2)
EB-430BE6-B01 C 11.77 kW 6.0 4 × ⌀300 8 5,033 None, Electric
Variants (2)
EB-245AC6-B01 C 12.01 kW 6.0 2 × ⌀450 17 10,218 None, Electric
Variants (2)
EB-240AE7-B01 C 12.25 kW 7.0 2 × ⌀400 13 6,462 None, Electric
Variants (2)
EB-430BE4-B01 C 12.58 kW 4.2 4 × ⌀300 7 4,802 None, Electric
Variants (2)
EB-240AE6-B01 C 12.88 kW 6.0 2 × ⌀400 13 6,359 None, Electric
Variants (2)
EB-335AC4-B01 C 12.96 kW 4.2 3 × ⌀350 13 7,763 None, Electric
Variants (2)
EB-245AC4-B01 C 13.21 kW 4.2 2 × ⌀450 16 9,711 None, Electric
Variants (2)
EB-340AC7-B01 C 14.19 kW 7.0 3 × ⌀400 14 10,511 None, Electric
Variants (2)
EB-240AE4-B01 C 14.33 kW 4.2 2 × ⌀400 12 6,038 None, Electric
Variants (2)
EB-245AE7-B01 C 14.35 kW 7.0 2 × ⌀450 16 9,208 None, Electric
Variants (2)
EB-245AE7-B07 C 14.65 kW 7.0 2 × ⌀450 16 9,661 None, Electric
Variants (2)
EB-335AE7-B01 C 14.71 kW 7.0 3 × ⌀350 12 7,516 None, Electric
Variants (2)
EB-435AC7-B01 C 14.83 kW 7.0 4 × ⌀350 14 10,824 None, Electric
Variants (2)
EB-245AE6-B01 C 14.90 kW 6.0 2 × ⌀450 16 8,991 None, Electric
Variants (2)
EB-340AC6-B01 C 15.34 kW 6.0 3 × ⌀400 14 10,378 None, Electric
Variants (2)
EB-335AE6-B01 C 15.49 kW 6.0 3 × ⌀350 12 7,391 None, Electric
Variants (2)
EB-435AC6-B01 C 15.77 kW 6.0 4 × ⌀350 14 10,696 None, Electric
Variants (2)
EB-345AC7-B01 C 16.56 kW 7.0 3 × ⌀450 18 15,607 None, Electric
Variants (2)
EB-345AC7-B07 C 16.79 kW 7.0 3 × ⌀450 19 16,222 None, Electric
Variants (2)
EB-245AE4-B01 C 17.06 kW 4.2 2 × ⌀450 15 8,381 None, Electric
Variants (2)
EB-335AE4-B01 C 17.18 kW 4.2 3 × ⌀350 12 7,016 None, Electric
Variants (2)
EB-340AC4-B01 C 17.40 kW 4.2 3 × ⌀400 14 10,027 None, Electric
Variants (2)
EB-435AC4-B01 C 18.17 kW 4.2 4 × ⌀350 13 10,350 None, Electric
Variants (2)
EB-440AC7-B01 C 18.62 kW 7.0 4 × ⌀400 15 14,008 None, Electric
Variants (2)
EB-435AE7-B01 C 18.74 kW 7.0 4 × ⌀350 13 10,020 None, Electric
Variants (2)
EB-340AE7-B01 C 18.81 kW 7.0 3 × ⌀400 13 9,690 None, Electric
Variants (2)
EB-345AC6-B01 C 19.46 kW 6.0 3 × ⌀450 18 15,313 None, Electric
Variants (2)
EB-435AE6-B01 C 19.69 kW 6.0 4 × ⌀350 13 9,854 None, Electric
Variants (2)
EB-340AE6-B01 C 19.74 kW 6.0 3 × ⌀400 13 9,536 None, Electric
Variants (2)
EB-440AC6-B01 C 19.79 kW 6.0 4 × ⌀400 15 13,833 None, Electric
Variants (2)
EB-345AC4-B01 C 19.84 kW 4.2 3 × ⌀450 17 14,566 None, Electric
Variants (2)
EB-340AE4-B01 C 21.17 kW 4.2 3 × ⌀400 13 9,057 None, Electric
Variants (2)
EB-445AC7-B01 C 21.23 kW 7.0 4 × ⌀450 19 20,790 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.