Skip to Content

EB (General)

Application
Cubic, Commercial
Air discharge
Single
Refrigerants
R134a, R22, R290, R32, R404A, R407A, R407B, R407C, R407F, R410A, R448A, R449A, R450a, R452a, R454A, R454C, R455A, R507A, R513a, R744
Capacity
0.64–32.06 kW
Fans
⌀200, ⌀250, ⌀300, ⌀350, ⌀400, ⌀450 mm
Max. working pressure
25 bar
EB (General)

Model nomenclature

How to read the model codes of this series, with an example.

  • A
    Model code (series) EB = EB - economical unit cooler
  • B
    Number of fans — Number of fans (one digit).
  • C
    Fan diameter — Fan diameter in cm (two digits; x10 = mm), e.g. 30=Ø300, 63=Ø630, 91=Ø910. 20 = Ø200 mm25 = Ø250 mm30 = Ø300 mm35 = Ø350 mm40 = Ø400 mm45 = Ø450 mm
  • D
    Dimensional data - coil size letter — First letter of Karyer's "dimensional data". With the fan count and diameter it fixes the finned coil length and the tubes per row (one casing size). It is a catalogue size index, not a measure: take dimensions from the model datasheet.
  • E
    Dimensional data - tube rows — Second letter of the dimensional data = number of tube rows (coil depth): A=2, B=3, C=4, D=5, E=6, G=8, I=10, K=12 (alphabet position + 1). A = 2 tube rowsB = 3 tube rowsC = 4 tube rowsE = 6 tube rows
  • F
    Fin spacing — Nominal fin spacing in mm (1-2 digits). Karyer catalogue: 4=4.20, 6=6.00. The exact pitch is per model (e.g. 4 covers 3.8 to 4.6 mm). 4 = Fin spacing about 4 mm6 = Fin spacing about 6 mm7 = Fin spacing about 7 mm
  • G
    Generation code — Karyer design generation letter; Karyer publishes no further decoding. B = Generation BC = Generation C
  • H
    Fan data 01 = Ø300: 230V/1Ph/50Hz, 4-pole; Ø350: 230V/1Ph/50Hz, 4-pole; Ø400: 230V/1Ph/50Hz, 4-pole; Ø450: 230V/1Ph/50Hz, 4-pole05 = Ø200: 230V/1Ph/50Hz, 4-pole; Ø250: 230V/1Ph/50Hz, 4-pole; Ø300: 230V/1Ph/50Hz, 4-pole07 = Ø450: 400V/3Ph/50Hz, 4-pole
  • J
    Option suffix (variant) — Optional, on BRI variant codes only: " ED" = electric defrost variant; no suffix = standard variant. ED = Electric defrost
Model Cooling capacity [kW] i Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 % Fin spacing [mm] Fans Air throw [m] Air flow [m³/h] Defrost Variants
EB-330BB4-B01 C 6.54 kW 4.2 3 × ⌀300 8 4,258 None, Electric
Variants (2)
EB-430AB6-B01 C 6.57 kW 6.0 4 × ⌀300 8 5,552 None, Electric
Variants (2)
EB-430BB7-B01 C 6.69 kW 7.0 4 × ⌀300 9 5,926 None, Electric
Variants (2)
EB-145AC4-B01 C 6.70 kW 4.2 1 × ⌀450 15 4,854 None, Electric
Variants (2)
EB-330AC4-B01 C 6.82 kW 4.2 3 × ⌀300 7 3,717 None, Electric
Variants (2)
EB-330BC6-B01 C 6.82 kW 6.0 3 × ⌀300 8 4,164 None, Electric
Variants (2)
EB-140AE4-B01 C 6.85 kW 4.2 1 × ⌀400 11 3,020 None, Electric
Variants (2)
EB-330AE7-B05 C 6.87 kW 7.0 3 × ⌀300 6 3,053 None, Electric
Variants (2)
EB-430AC7-B05 C 6.96 kW 7.0 4 × ⌀300 7 4,673 None, Electric
Variants (2)
EB-145AE7-B01 C 7.00 kW 7.0 1 × ⌀450 14 4,605 None, Electric
Variants (2)
EB-425BC4-B05 C 7.03 kW 4.2 4 × ⌀250 6 3,306 None, Electric
Variants (2)
EB-430BB6-B05 C 7.11 kW 6.0 4 × ⌀300 8 5,272 None, Electric
Variants (2)
EB-145AE7-B07 C 7.14 kW 7.0 1 × ⌀450 15 4,832 None, Electric
Variants (2)
EB-430AB4-B05 C 7.15 kW 4.2 4 × ⌀300 7 4,726 None, Electric
Variants (2)
EB-330AE6-B05 C 7.23 kW 6.0 3 × ⌀300 6 2,972 None, Electric
Variants (2)
EB-235AC7-B01 C 7.29 kW 7.0 2 × ⌀350 13 5,413 None, Electric
Variants (2)
EB-330BC4-B05 C 7.35 kW 4.2 3 × ⌀300 7 3,544 None, Electric
Variants (2)
EB-330AE4-B05 C 7.35 kW 4.2 3 × ⌀300 6 2,787 None, Electric
Variants (2)
EB-430BB6-B01 C 7.37 kW 6.0 4 × ⌀300 9 5,858 None, Electric
Variants (2)
EB-430AC6-B05 C 7.42 kW 6.0 4 × ⌀300 7 4,578 None, Electric
Variants (2)
EB-145AE6-B01 C 7.43 kW 6.0 1 × ⌀450 14 4,495 None, Electric
Variants (2)
EB-430AB4-B01 C 7.44 kW 4.2 4 × ⌀300 8 5,328 None, Electric
Variants (2)
EB-430AC7-B01 C 7.52 kW 7.0 4 × ⌀300 8 5,273 None, Electric
Variants (2)
EB-330BE7-B05 C 7.65 kW 7.0 3 × ⌀300 7 3,386 None, Electric
Variants (2)
EB-330BC4-B01 C 7.67 kW 4.2 3 × ⌀300 8 3,995 None, Electric
Variants (2)
EB-330AE7-B01 C 7.69 kW 7.0 3 × ⌀300 7 3,559 None, Electric
Variants (2)
EB-430BC7-B05 C 7.73 kW 7.0 4 × ⌀300 8 5,048 None, Electric
Variants (2)
EB-235AC6-B01 C 7.88 kW 6.0 2 × ⌀350 13 5,348 None, Electric
Variants (2)
EB-430AC6-B01 C 7.97 kW 6.0 4 × ⌀300 8 5,182 None, Electric
Variants (2)
EB-330BE6-B05 C 8.03 kW 6.0 3 × ⌀300 7 3,306 None, Electric
Variants (2)
EB-330BE4-B05 C 8.09 kW 4.2 3 × ⌀300 6 3,101 None, Electric
Variants (2)
EB-330AE6-B01 C 8.11 kW 6.0 3 × ⌀300 7 3,483 None, Electric
Variants (2)
EB-430BB4-B05 C 8.20 kW 4.2 4 × ⌀300 8 5,096 None, Electric
Variants (2)
EB-330AE4-B01 C 8.22 kW 4.2 3 × ⌀300 7 3,287 None, Electric
Variants (2)
EB-430BC7-B01 C 8.29 kW 7.0 4 × ⌀300 8 5,636 None, Electric
Variants (2)
EB-430BC6-B05 C 8.32 kW 6.0 4 × ⌀300 8 4,960 None, Electric
Variants (2)
EB-330BE7-B01 C 8.40 kW 7.0 3 × ⌀300 8 3,842 None, Electric
Variants (2)
EB-145AE4-B01 C 8.45 kW 4.2 1 × ⌀450 13 4,191 None, Electric
Variants (2)
EB-430AC4-B05 C 8.45 kW 4.2 4 × ⌀300 7 4,312 None, Electric
Variants (2)
EB-430BB4-B01 C 8.77 kW 4.2 4 × ⌀300 8 5,678 None, Electric
Variants (2)
EB-330BE6-B01 C 8.82 kW 6.0 3 × ⌀300 7 3,775 None, Electric
Variants (2)
EB-430BC6-B01 C 8.95 kW 6.0 4 × ⌀300 8 5,554 None, Electric
Variants (2)
EB-330BE4-B01 C 8.98 kW 4.2 3 × ⌀300 7 3,603 None, Electric
Variants (2)
EB-240AC7-B01 C 9.07 kW 7.0 2 × ⌀400 14 7,005 None, Electric
Variants (2)
EB-430AC4-B01 C 9.10 kW 4.2 4 × ⌀300 8 4,956 None, Electric
Variants (2)
EB-235AC4-B01 C 9.15 kW 4.2 2 × ⌀350 12 5,174 None, Electric
Variants (2)
EB-430AE7-B05 C 9.17 kW 7.0 4 × ⌀300 6 4,070 None, Electric
Variants (2)
EB-430BC4-B05 C 9.18 kW 4.2 4 × ⌀300 7 4,726 None, Electric
Variants (2)
EB-430AE4-B05 C 9.56 kW 4.2 4 × ⌀300 6 3,716 None, Electric
Variants (2)
EB-430AE6-B05 C 9.64 kW 6.0 4 × ⌀300 6 3,963 None, Electric
Variants (2)

Nominal conditions: refrigerant R404A, evaporation (dew point) −8 °C, inlet air 0 °C, humidity 85 %

Downloads

Ask about product

Our engineers answer with a selection for your conditions.

Thank you. We received your enquiry and will get back to you shortly.

The data are illustrative and may change without notice. Capacities are interpolated from the manufacturer's rating grid; points the manufacturer did not rate are shown as "not rated" and never estimated.

Compare 0 / 4 Open comparison You can compare up to 4 units; remove one before adding another.